TRACOPOWER TVN 5WI DC-DC Converter, ±24V dc/ ±100mA Output, 4.5 → 12 V dc Input, 5W, Through Hole, +85°C Max

Bulk discount available

Subtotal (1 tube of 10 units)*

£579.48

(exc. VAT)

£695.38

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from 06 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Tube(s)
Per Tube
Per unit*
1 - 4£579.48£57.948
5 - 9£562.09£56.209
10 - 24£544.72£54.472
25 - 49£521.53£52.153
50 +£498.36£49.836

*price indicative

RS Stock No.:
146-5970
Mfr. Part No.:
TVN 5-0925WI
Brand:
TRACOPOWER
Find similar products by selecting one or more attributes.
Select all

Brand

TRACOPOWER

Output Voltage

±24V dc

Input Voltage Range

4.5 → 12 V dc

Power Rating

5W

Input Voltage Nominal

9 V dc

Output Current

±100mA

Mounting Type

Through Hole

Isolated

Yes

Number of Outputs

2

Output Voltage Adjustment Range

±21.6 V dc, ±26.4V dc

Package

DIP-24

Isolation Voltage

1.6kV dc

Depth

10.2mm

Length

32mm

Width

20mm

Series

TVN 5WI

Load Regulation

0.01

Standards Met

EN 55032, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, IEC/EN/UL 60950-1, MIL-STD-810F

Maximum Temperature

+85°C

Efficiency

87%

Minimum Temperature

-40°C

COO (Country of Origin):
TW
The TVN 5WI series is a ultra low ripple and noise 5 Watt dc/dc converter featuring wide 4:1 input voltage ranges in a DIP-24 package. Standard features include remote On/Off, over voltage protection, under voltage lockout and short circuit protection. High efficiency across load range and low input current characteristics at no load make these converters the ideal solution for many operations which require low ripple and noise characteristics.

I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP
Risk management process according to ISO 14971 including risk management file
Extended operating temperature range –40°C to 85°C.
EMC compliance to IEC 60601-1-2 4th edition and EN55032 class A