TRACOPOWER THM 6 DC-DC Converter, 12V dc/ 500mA Output, 18 → 36 V dc Input, 6W, PCB Mount, +90°C Max Temp -40°C
- RS Stock No.:
- 135-0572
- Mfr. Part No.:
- THM 6-2412
- Brand:
- TRACOPOWER
Bulk discount available
Subtotal (1 tube of 10 units)*
£384.76
(exc. VAT)
£461.71
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 11 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Tube(s) | Per Tube | Per unit* |
---|---|---|
1 - 4 | £384.76 | £38.476 |
5 - 9 | £373.21 | £37.321 |
10 - 24 | £361.67 | £36.167 |
25 - 49 | £346.29 | £34.629 |
50 + | £330.89 | £33.089 |
*price indicative
- RS Stock No.:
- 135-0572
- Mfr. Part No.:
- THM 6-2412
- Brand:
- TRACOPOWER
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | TRACOPOWER | |
Output Voltage | 12V dc | |
Input Voltage Range | 18 → 36 V dc | |
Power Rating | 6W | |
Input Voltage Nominal | 24 V dc | |
Output Current | 500mA | |
Mounting Type | PCB Mount | |
Isolated | Yes | |
Number of Outputs | 1 | |
Package | DIP-24 | |
Isolation Voltage | 5kV ac | |
Width | 20.3mm | |
Depth | 10.2mm | |
Length | 31.8mm | |
Series | THM 6 | |
Load Regulation | 0.002 | |
Minimum Temperature | -40°C | |
Medical Approved | Yes | |
Efficiency | 89% | |
Maximum Temperature | +90°C | |
Standards Met | ANSI/AAMI ES60601-1:2005/(R)2012, CB Scheme IEC 606010-1, cULus Recognised, ES60601-1, IEC/EN 60601-1 | |
Select all | ||
---|---|---|
Brand TRACOPOWER | ||
Output Voltage 12V dc | ||
Input Voltage Range 18 → 36 V dc | ||
Power Rating 6W | ||
Input Voltage Nominal 24 V dc | ||
Output Current 500mA | ||
Mounting Type PCB Mount | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Package DIP-24 | ||
Isolation Voltage 5kV ac | ||
Width 20.3mm | ||
Depth 10.2mm | ||
Length 31.8mm | ||
Series THM 6 | ||
Load Regulation 0.002 | ||
Minimum Temperature -40°C | ||
Medical Approved Yes | ||
Efficiency 89% | ||
Maximum Temperature +90°C | ||
Standards Met ANSI/AAMI ES60601-1:2005/(R)2012, CB Scheme IEC 606010-1, cULus Recognised, ES60601-1, IEC/EN 60601-1 | ||
TRACOPOWER THM 6 Series DC-DC Converter, 12V DC Output Voltage, 6W Power Rating - THM 6-2412
This isolated DC-DC converter is a medical-grade power supply designed to efficiently step down from 24V to 12V. With its compact DIP-24 plastic case, the unit is ideal for PCB mounting in various applications. Operating within a wide input voltage range of 18 to 36V DC, it ensures high reliability and performance under demanding conditions.
Features & Benefits
• Reinforced isolation rated at 5000VAC enhances safety
• High efficiency of 89% reduces energy waste
• Operating temperature range from -40°C to +90°C ensures versatility
• Low leakage current of less than 2 00B5 (μ) A increases safety in medical places
• Compliant with IEC 60601-1 standards for medical devices
• Compact size ideal for space-constrained designs
• High efficiency of 89% reduces energy waste
• Operating temperature range from -40°C to +90°C ensures versatility
• Low leakage current of less than 2 00B5 (μ) A increases safety in medical places
• Compliant with IEC 60601-1 standards for medical devices
• Compact size ideal for space-constrained designs
Applications
• Utilised in medical equipment where high reliability is crucial
• Suitable for control and measurement devices in automation systems
• Employed in transportation systems requiring stable power
• Integrated into IGBT drivers for industrial
• Suitable for control and measurement devices in automation systems
• Employed in transportation systems requiring stable power
• Integrated into IGBT drivers for industrial
What type of mounting options are available for this converter?
The unit is designed for PCB mounting, making it suitable for easy integration into printed circuit boards.
How does this converter manage safety with its isolation features?
The reinforced isolation system provides a safety barrier rated at 5000VAC, ensuring protection against electric shock and interference.
What is the typical current output of this DC-DC converter under nominal conditions?
At its nominal output voltage of 12V, the device delivers an output current of 500mA.
Can this converter operate in extreme temperatures?
Yes, it operates effectively within a temperature range of -40°C to +90°C, making it versatile for various environments.
Related links
- TRACOPOWER THM 6 DC-DC Converter 36 → 75 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 9 → 18 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 4.5 → 9 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 36 → 75 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 18 → 36 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 18 → 36 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 18 → 36 V dc Input PCB Mount, +90°C Max Temp -40°C
- TRACOPOWER THM 6 DC-DC Converter 36 → 75 V dc Input PCB Mount, +90°C Max Temp -40°C