Honeywell CSN Series Current Transformer 36 A 1:1000 to 1:5000 15 V
- RS Stock No.:
- 189-5477
- Mfr. Part No.:
- CSNE151
- Brand:
- Honeywell
Subtotal (1 unit)*
£68.14
(exc. VAT)
£81.77
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 20 unit(s) shipping from 23 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £68.14 |
*price indicative
- RS Stock No.:
- 189-5477
- Mfr. Part No.:
- CSNE151
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Product Type | Current Transformer | |
| Series | CSN | |
| Secondary Current | 25 to 50 mA | |
| Terminal Type | 3-Pin | |
| Minimum Operating Temperature | 0°C | |
| Primary Current | 36A | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | No | |
| Mount Type | PCB | |
| Maximum Operating Frequency | 150kHz | |
| Minimum Operating Frequency | 0Hz | |
| Turns Ratio | 1:1000 to 1:5000 | |
| Supply Voltage | 15 V | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Product Type Current Transformer | ||
Series CSN | ||
Secondary Current 25 to 50 mA | ||
Terminal Type 3-Pin | ||
Minimum Operating Temperature 0°C | ||
Primary Current 36A | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals No | ||
Mount Type PCB | ||
Maximum Operating Frequency 150kHz | ||
Minimum Operating Frequency 0Hz | ||
Turns Ratio 1:1000 to 1:5000 | ||
Supply Voltage 15 V | ||
- COO (Country of Origin):
- CN
High current & Multi-range (AC & DC)
Flexible alternative to the current shunt or transformers for the isolated measurement of a.c. or d.c. currents. Both types have plastic Bayblend KU1468 UL94-VO cases.,High current types have current sensors based on the hall effect and null balance method. The output is the balancing current which is a perfect image of the primary current reduced by the number of secondary turns at any time. It can be expressed as a voltage by passing it through a resistor.,Multi-range types are similar devices but with a wider measuring range. Up to 36A is possible using 5 primary turns and up to 43A using 7 primary turns.
Related links
- Honeywell CSN Series Current Transformer 56:1 15 V dc
- Honeywell CSN Series Current Transformer 90:1 12 → 15 V dc
- LEM LA Series Current Transformer 36:1 15 V
- Honeywell CSN Series Current Transformer 60 mA ±15 V
- Honeywell CSN Series Current Transformer 600:1 26mm Bore, 15 V
- Honeywell CSN Series Current Transformer 200:1 12 → 15 V dc
- Honeywell CSN Series Closed Loop Current Transducer 25mA output current
- LEM LV Series Current Transformer 14:1 12 → 15 V