LEM LA Series Closed Loop Current Sensor, 0 → 70A nominal current, 50mArms output current

  • RS Stock No. 180-7357
  • Mfr. Part No. LA 55-P
  • Brand LEM
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

LA-P Series

Compensated closed-loop Hall effect current transducers for the measurement of continuous, alternating, pulsed and mixed currents

Excellent dynamic performance
Good linearity and low temperature drift
Galvanic isolation between input and measuring circuit
PCB mounting
Body material plastic to UL 94-V0

//media.rs-online.com/t_line/L286311-01.gif
Specifications
Attribute Value
Sensor Technology Closed Loop
Nominal Current 0 → 70A
Output Current Range 50mArms
Supply Voltage 12 → 15 V
Sensor Type Hall Effect
Mounting Type PCB Mount
Frequency Bandwidth DC to 200 kHz
Accuracy ±0.9 %
Minimum Operating Temperature -40°C
Series LA
Maximum Operating Temperature +85°C
Depth 14.45mm
Height 27.6mm
Width 36.6mm
328 In stock for FREE next working day delivery
Price Each
£ 18.01
(exc. VAT)
£ 21.61
(inc. VAT)
Units
Per unit
1 - 4
£18.01
5 - 9
£17.47
10 +
£16.72
Related Products
Open loop current transducer with Hall effect measuring ...
Description:
Open loop current transducer with Hall effect measuring principleFor measuring DC, AC and pulse currentsWith galvanic separation between primary and secondary circuitsUnipolar voltage supplyFixed offset voltage with corresponding amplificationHousing made from insulating, self-extinguishing material UL94-V0.
CSLW Series miniature, open-loop AC current sensors from ...
Description:
CSLW Series miniature, open-loop AC current sensors from Honeywell. These sensors have a ratiometric output and incorporate a miniature linear Hall-effect sensor which is encapsulated in a PCB-mountable plastic package. A complete sensor is comprised of a sensor IC, flux collector, housing, and wound wire coil. The compact size is ...
The Honeywell CNS series of closed loop Hall-effect ...
Description:
The Honeywell CNS series of closed loop Hall-effect current sensors utilise the null balance or zero magnetic flux feedback method to provide accurate and repeatable measurements. The devices produce an output current which can be converted to a voltage by using a suitable load resistor. • Measures AC, DC and ...
Measurement of dc currentsLarge apertureEasy panel mountingNo insertion ...
Description:
Measurement of dc currentsLarge apertureEasy panel mountingNo insertion lossesSupply voltage 20/50Vdc - 22/38VacAccuracy ±1%Size (HxWxD) 57.2 x 30 x 89.7mmOperating Temperature -20 → +50°CWeight 100g.