RS PRO 12VA 2 Output Chassis Mounting Transformer, 6V ac

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

Chassis Mount, Clamp Construction, 230Vac, 6VA to 50VA

Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps
Solder tag terminations
Optional terminal shrouds (example 503-912 )
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Standards

BS3535; EN 60 742

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 6V ac
Power Rating 12VA
Number of Outputs 2
Mounting Type Clamp Mount
Length 59mm
Width 50mm
Depth 50mm
Dimensions 59 x 50 x 50mm
Fixing Hole Diameter 4.7 x 8.7mm
Weight 400g
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Sorry, we couldn't check our stock levels right now. Please try refreshing the page.
Price Each
£ 10.17
(exc. VAT)
£ 12.20
(inc. VAT)
Units
Per unit
1 - 9
£10.17
10 +
£9.62
Not available for guaranteed pre 9am/10am delivery
Related Products
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from 400 to 2500 VA).Panel mounting using 4 screws. Double section ...
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Fully shrouded bobbins Extra pins for secure board mounting 100% electrical and flash tested Tested ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist. Type UI 30 - 3 VA → 10 VA. Encapsulated – Toroidal.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...