ETA Thermal Circuit Breaker - 3120 2 Pole 250V Voltage Rating Snap In, 3A Current Rating
- RS Stock No.:
- 286-3982
- Mfr. Part No.:
- 3120-F551-H7T1-W02D-3A
- Brand:
- ETA
Image representative of range
Discontinued
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£16.80
(exc. VAT)
£20.16
(inc. VAT)
- RS Stock No.:
- 286-3982
- Mfr. Part No.:
- 3120-F551-H7T1-W02D-3A
- Brand:
- ETA
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ETA | |
| Current Rating | 3A | |
| Number of Poles | 2 | |
| Voltage Rating | 250V | |
| Width | 25mm | |
| Series | 3120 | |
| Tripping Mechanism | Thermal | |
| Reset Actuator Type | Rocker | |
| Rated AC Voltage | 250V | |
| Mounting Style | Snap In | |
| Overall Length | 41mm | |
| Circuit Breaker Type | Thermal Circuit Breaker | |
| Overall Dimensions | 41 x 25 x 35mm | |
| Terminal Contact Type | Blade | |
| Overall Depth | 35mm | |
| Rated DC Voltage | 50V | |
| Select all | ||
|---|---|---|
Brand ETA | ||
Current Rating 3A | ||
Number of Poles 2 | ||
Voltage Rating 250V | ||
Width 25mm | ||
Series 3120 | ||
Tripping Mechanism Thermal | ||
Reset Actuator Type Rocker | ||
Rated AC Voltage 250V | ||
Mounting Style Snap In | ||
Overall Length 41mm | ||
Circuit Breaker Type Thermal Circuit Breaker | ||
Overall Dimensions 41 x 25 x 35mm | ||
Terminal Contact Type Blade | ||
Overall Depth 35mm | ||
Rated DC Voltage 50V | ||
- COO (Country of Origin):
- TN
CBE, 1 Pole Sensing, 2 Pole Switching, 3120 Series
IEC Classification S/TO (with module, S/TM),This range of low cost switch and circuit breaker are an economic way of providing basic protection for equipment.,Typical tripping times at 2xIN, 20-30 seconds faster time can be achieved with the addition of the magnetic module; refer to accessories below.,Circuit protection designed for equipment, sub-systems and components.
Depth behind panel: 43mm
Approvals
UL, CSA, VDE, BV
Thermal Magnetic Convertible
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).
Related links
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 3A Current Rating
- ETA Thermal Circuit Breaker - 3120 2 Pole 250V Voltage Rating Snap In, 16A Current Rating
- ETA Thermal Circuit Breaker / Switch - 2 Pole Snap In, 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 2 Pole 50 V DC 3A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 10A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 20A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 1A Current Rating