RS PRO Solid State Relay, 10 A rms Load, Panel Mount, 480 V ac Load, 32 V dc Control
- RS Stock No.:
- 922-5126
- Brand:
- RS PRO
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£102.00
(exc. VAT)
£122.40
(inc. VAT)
- RS Stock No.:
- 922-5126
- Brand:
- RS PRO
Select all | Attribute | Value |
|---|---|---|
| Brand | RS PRO | |
| Maximum Load Current | 10 A rms | |
| Mounting Type | Panel Mount | |
| Maximum Load Voltage | 480 V ac | |
| Minimum Load Voltage | 48 V ac | |
| Minimum Control Voltage | 3 V dc | |
| Maximum Control Voltage | 32 V dc | |
| Switching Type | Random | |
| Control Voltage Range | 3 → 32 V dc | |
| Minimum Load Current | 0.1 A | |
| Number of Poles | 3 | |
| Terminal Type | Screw | |
| Contact Configuration | 3P-NO | |
| Output Device | Thyristor | |
| Relay Type | AC | |
| Maximum Turn On Time | 0.1ms | |
| Load Voltage Range | 48 → 480V ac | |
| Dimensions | 107 x 73.5 x 27mm | |
| Standards Met | CE | |
| Special Features | Its able to Switch Three Phase Loads with One Control Signal up to Rated Line Currents of 45A and Line Voltages up to 480Vac, Maxi Puck Housing, Panel Mounted, The WG A3 has High Noise Immunity and an Internal Overvoltage Protection which becomes Effective at 1000 V | |
| Operating Temperature Range | -20 → +80°C | |
| Length | 107mm | |
| Depth | 73.5mm | |
| Height | 27mm | |
| Off State Leakage Current | 10 mA | |
| Select all | ||
|---|---|---|
Brand RS PRO | ||
Maximum Load Current 10 A rms | ||
Mounting Type Panel Mount | ||
Maximum Load Voltage 480 V ac | ||
Minimum Load Voltage 48 V ac | ||
Minimum Control Voltage 3 V dc | ||
Maximum Control Voltage 32 V dc | ||
Switching Type Random | ||
Control Voltage Range 3 → 32 V dc | ||
Minimum Load Current 0.1 A | ||
Number of Poles 3 | ||
Terminal Type Screw | ||
Contact Configuration 3P-NO | ||
Output Device Thyristor | ||
Relay Type AC | ||
Maximum Turn On Time 0.1ms | ||
Load Voltage Range 48 → 480V ac | ||
Dimensions 107 x 73.5 x 27mm | ||
Standards Met CE | ||
Special Features Its able to Switch Three Phase Loads with One Control Signal up to Rated Line Currents of 45A and Line Voltages up to 480Vac, Maxi Puck Housing, Panel Mounted, The WG A3 has High Noise Immunity and an Internal Overvoltage Protection which becomes Effective at 1000 V | ||
Operating Temperature Range -20 → +80°C | ||
Length 107mm | ||
Depth 73.5mm | ||
Height 27mm | ||
Off State Leakage Current 10 mA | ||
- COO (Country of Origin):
- BE