Celduc SAL9-SAM9 Series Solid State Relay, 35 A Load, DIN Rail Mount, 280 V ac Load, 32 V dc Control
- RS Stock No.:
- 917-2693
- Mfr. Part No.:
- SAM943460
- Brand:
- Celduc
- RS Stock No.:
- 917-2693
- Mfr. Part No.:
- SAM943460
- Brand:
- Celduc
Select all | Attribute | Value |
|---|---|---|
| Brand | Celduc | |
| Maximum Load Current | 35 A | |
| Mounting Type | DIN Rail | |
| Maximum Load Voltage | 280 V ac | |
| Minimum Load Voltage | 12 V ac | |
| Maximum Control Voltage | 32 V dc | |
| Minimum Control Voltage | 3 V dc | |
| Switching Type | Zero Cross | |
| Control Voltage Range | 3 → 32 V dc | |
| Range | SAM9 | |
| Minimum Load Current | 5 mA | |
| Number of Poles | 1 | |
| Terminal Type | Screw | |
| Output Device | Thyristor | |
| Relay Type | Single Phase Solid State Contactor | |
| Maximum Turn On Time | 10ms | |
| Series | SAL9-SAM9 | |
| Load Voltage Range | 12 → 280V ac | |
| Dimensions | 45 x 112 x 90mm | |
| Depth | 112mm | |
| Operating Temperature Range | -55 → +100°C | |
| Standards Met | CE, cURus 100kA, EAC | |
| Maximum Operating Temperature | +100°C | |
| Length | 45mm | |
| Off State Leakage Current | 1 mA | |
| Height | 90mm | |
| Special Features | Zero Cross Solid State Contactor Especially Designed for Resistive Loads, Yellow LED Visualization on The Input, Input Over-Voltage Protection | |
| Minimum Operating Temperature | -55°C | |
| Select all | ||
|---|---|---|
Brand Celduc | ||
Maximum Load Current 35 A | ||
Mounting Type DIN Rail | ||
Maximum Load Voltage 280 V ac | ||
Minimum Load Voltage 12 V ac | ||
Maximum Control Voltage 32 V dc | ||
Minimum Control Voltage 3 V dc | ||
Switching Type Zero Cross | ||
Control Voltage Range 3 → 32 V dc | ||
Range SAM9 | ||
Minimum Load Current 5 mA | ||
Number of Poles 1 | ||
Terminal Type Screw | ||
Output Device Thyristor | ||
Relay Type Single Phase Solid State Contactor | ||
Maximum Turn On Time 10ms | ||
Series SAL9-SAM9 | ||
Load Voltage Range 12 → 280V ac | ||
Dimensions 45 x 112 x 90mm | ||
Depth 112mm | ||
Operating Temperature Range -55 → +100°C | ||
Standards Met CE, cURus 100kA, EAC | ||
Maximum Operating Temperature +100°C | ||
Length 45mm | ||
Off State Leakage Current 1 mA | ||
Height 90mm | ||
Special Features Zero Cross Solid State Contactor Especially Designed for Resistive Loads, Yellow LED Visualization on The Input, Input Over-Voltage Protection | ||
Minimum Operating Temperature -55°C | ||
- COO (Country of Origin):
- FR
Celduc SAL/SAM Series Solid State Relays
Over-voltage protection
LED indicator