Omron G3PA Series Solid State Relay, 30 A Load, DIN Rail Mount, 528 V ac Load, 30 V dc Control
- RS Stock No.:
- 828-6858
- Mfr. Part No.:
- G3PA-430B-VD-2 DC12-24
- Brand:
- Omron
Unavailable
RS will no longer stock this product.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£194.12
(exc. VAT)
£232.94
(inc. VAT)
- RS Stock No.:
- 828-6858
- Mfr. Part No.:
- G3PA-430B-VD-2 DC12-24
- Brand:
- Omron
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Omron | |
| Maximum Load Current | 30 A | |
| Mounting Type | DIN Rail | |
| Maximum Load Voltage | 528 V ac | |
| Minimum Load Voltage | 180 V ac | |
| Minimum Control Voltage | 9.6 V dc | |
| Maximum Control Voltage | 30 V dc | |
| Switching Type | Zero Cross | |
| Control Voltage Range | 9.6 → 30 V dc | |
| Minimum Load Current | 0.5 A | |
| Terminal Type | Screw | |
| Contact Configuration | SPST | |
| Output Device | Phototriac Coupler | |
| Load Voltage Range | 180 → 528V ac | |
| Maximum Turn On Time | 1/2 cycle | |
| Series | G3PA | |
| Dimensions | 47 x 100 x 100mm | |
| Depth | 100mm | |
| Operating Temperature Range | -30 → +80°C | |
| Maximum Operating Temperature | +80°C | |
| Length | 47mm | |
| Height | 100mm | |
| Off State Leakage Current | 20 mA | |
| Select all | ||
|---|---|---|
Brand Omron | ||
Maximum Load Current 30 A | ||
Mounting Type DIN Rail | ||
Maximum Load Voltage 528 V ac | ||
Minimum Load Voltage 180 V ac | ||
Minimum Control Voltage 9.6 V dc | ||
Maximum Control Voltage 30 V dc | ||
Switching Type Zero Cross | ||
Control Voltage Range 9.6 → 30 V dc | ||
Minimum Load Current 0.5 A | ||
Terminal Type Screw | ||
Contact Configuration SPST | ||
Output Device Phototriac Coupler | ||
Load Voltage Range 180 → 528V ac | ||
Maximum Turn On Time 1/2 cycle | ||
Series G3PA | ||
Dimensions 47 x 100 x 100mm | ||
Depth 100mm | ||
Operating Temperature Range -30 → +80°C | ||
Maximum Operating Temperature +80°C | ||
Length 47mm | ||
Height 100mm | ||
Off State Leakage Current 20 mA | ||
- COO (Country of Origin):
- JP
G3PA-430B-VD-2 DC12-24 SSR – Solid State Relay with Replaceable Power Cartridge.
The design of the heat sink provides a smaller SSR – solid state relay with easily maintained replaceable element cartridges. The relays are applicable with 3-phase loads. The G3PA series of SSR – solid state relays can be DIN rail mounted or mounted using screws.
Features and Benefits of G3PA-430B-VD-2 DC12-24 SSR –Solid state relay.
• Phototriac coupler.
• Zero cross function.
• Indicator.
• Rated output load 20 A at 200 to 480 V ac.
• Rated input voltage 12 to 24 V dc.
• VD – certified UL, CSA, VDE.
• Zero cross function.
• Indicator.
• Rated output load 20 A at 200 to 480 V ac.
• Rated input voltage 12 to 24 V dc.
• VD – certified UL, CSA, VDE.
SSR – Solid state relay Input Rating at 25°C ambient.
• Operating voltage range 9.6 to 30 V dc.
• Input current impedance 7 mA max.
• Must operate voltage 9.2 V dc max.
• Must release voltage 1 V dc.
• Input current impedance 7 mA max.
• Must operate voltage 9.2 V dc max.
• Must release voltage 1 V dc.
SSR – Solid state relay Output.
• Rated load voltage 200 to 480 V ac, 50 / 60 Hz.
• Load voltage range 180 to 528 V ac, 50/ 60 Hz.
• Load current 0.5 to 30 A at 30°C.
• Inrush current 440 A, 60 Hz, 1 cycle.
• VDRM 1200 V.
• Load voltage range 180 to 528 V ac, 50/ 60 Hz.
• Load current 0.5 to 30 A at 30°C.
• Inrush current 440 A, 60 Hz, 1 cycle.
• VDRM 1200 V.
Additional Features G3PA-430B-VD-2 DC12-24 SSR – Solid State Relay.
• Operate and release time of load power source cycle + 1 ms max (DC models). 1 pf load power source cycle + 1 ms max (AC input).
• Output ON voltage drop 1.8 V (RMS) max.
• Leakage current 20 mA max at 480 V ac
• Vibration resistance – destruction – 10 to 55 to 10 Hz, 0.375 mm single amplitude mounted to a DIN rail.
• Shock resistance – destruction – 300 m/s² mounted to a DIN rail.
• Operating temperature – ambient - -30°C to 80°C. No icing or condensation.
• Screw terminal.
• Relay weight 410 g.
• Output ON voltage drop 1.8 V (RMS) max.
• Leakage current 20 mA max at 480 V ac
• Vibration resistance – destruction – 10 to 55 to 10 Hz, 0.375 mm single amplitude mounted to a DIN rail.
• Shock resistance – destruction – 300 m/s² mounted to a DIN rail.
• Operating temperature – ambient - -30°C to 80°C. No icing or condensation.
• Screw terminal.
• Relay weight 410 g.
Replacing the SSR – Solid state relay cartridge.
• Turn OFF the power supply when replacing a cartridge.
• Damaged cartridges can be replaced without disconnecting the wires.
• If the temperature indicator changes from pink to red triac circuits may be malfunctioning, replace.
• Improve heat radiation efficiency before cartridge replacement.
• Damaged cartridges can be replaced without disconnecting the wires.
• If the temperature indicator changes from pink to red triac circuits may be malfunctioning, replace.
• Improve heat radiation efficiency before cartridge replacement.
What does Zero Cross Function mean in SSR in Solid State Relays?
Zero cross function will allow the relay to turn ON when the AC load power supply approaches 0 V suppressing any noise generated with a sudden load current increase. Zero cross function is effective across 2 types of noise, noise on power lines and noise emitted into open space.