Phoenix Contact Solid State Relay, 9 A Load, DIN Rail Mount, 440 V ac Load, 24 V dc Control
- RS Stock No.:
- 308-1490
- Mfr. Part No.:
- 2941701
- Brand:
- Phoenix Contact
Unavailable
RS will no longer stock this product.
- RS Stock No.:
- 308-1490
- Mfr. Part No.:
- 2941701
- Brand:
- Phoenix Contact
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Phoenix Contact | |
| Maximum Load Current | 9 A | |
| Mounting Type | DIN Rail | |
| Maximum Load Voltage | 440 V ac | |
| Minimum Load Voltage | 110 V ac | |
| Maximum Control Voltage | 24 V dc | |
| Terminal Type | Screw | |
| Output Device | Triac | |
| Load Voltage Range | 110 → 440V ac | |
| Maximum Turn On Time | 20ms | |
| Dimensions | 84 x 62 x 110mm | |
| Maximum Operating Temperature | +60°C | |
| Minimum Operating Temperature | -20°C | |
| Depth | 62mm | |
| Operating Temperature Range | -20 → +60°C | |
| Length | 84mm | |
| Off State Leakage Current | 7 mA | |
| Height | 110mm | |
| Select all | ||
|---|---|---|
Brand Phoenix Contact | ||
Maximum Load Current 9 A | ||
Mounting Type DIN Rail | ||
Maximum Load Voltage 440 V ac | ||
Minimum Load Voltage 110 V ac | ||
Maximum Control Voltage 24 V dc | ||
Terminal Type Screw | ||
Output Device Triac | ||
Load Voltage Range 110 → 440V ac | ||
Maximum Turn On Time 20ms | ||
Dimensions 84 x 62 x 110mm | ||
Maximum Operating Temperature +60°C | ||
Minimum Operating Temperature -20°C | ||
Depth 62mm | ||
Operating Temperature Range -20 → +60°C | ||
Length 84mm | ||
Off State Leakage Current 7 mA | ||
Height 110mm | ||
Non Compliant
- COO (Country of Origin):
- DE
ELR Series load and interface relay
Electronic interface relays replace an entire reversing contactor circuit - including control input and load wiring lock mechanism. Contactless switching in the voltage zero point does not generate additional high-frequency interfering pulses. Input and load end suppressors permit permanently reliable operation, even with inductive loads.
ELR 3 / 9-400
Electronic load relay with 62 mm overall width
Input voltage 24V dc
Operating indicator
Protective circuit in input and output
Input voltage 24V dc
Operating indicator
Protective circuit in input and output
ELR W3 / 9-400
Electronic interface relay with 62 mm overall width
Input voltage 24 Vdc
Load end 110–440 VAC maximum 9 A (see derating curve)
Input voltage 24 Vdc
Load end 110–440 VAC maximum 9 A (see derating curve)

Zero Voltage Relays
Note
Temperature can affect current rating; please consult the data sheet for potential derating.