Turck IM(X)12 Series Frequency Transducer, Frequency Input, Relay Output, 10 → 30V dc Supply, Ex, SIL, UL
- RS Stock No.:
- 281-6791
- Mfr. Part No.:
- IM12-FI01-1SF-1R-0/24VDC
- Brand:
- Turck
Subtotal (1 unit)*
£366.02
(exc. VAT)
£439.22
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 1 unit(s) shipping from 24 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £366.02 |
*price indicative
- RS Stock No.:
- 281-6791
- Mfr. Part No.:
- IM12-FI01-1SF-1R-0/24VDC
- Brand:
- Turck
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Turck | |
| Module Type | Frequency Transducer | |
| Input Signal Type | Frequency | |
| Output Signal Type | Relay | |
| Input Range | 3-Wire Input - 12 V dc, NAMUR Input - 8.2 V dc | |
| Output Range | = 30 VDC or = 250 VAC | |
| Supply Voltage | 10 → 30V dc | |
| Hazardous Area Certification | Ex, SIL, UL | |
| Series | IM(X)12 | |
Select all | ||
|---|---|---|
Brand Turck | ||
Module Type Frequency Transducer | ||
Input Signal Type Frequency | ||
Output Signal Type Relay | ||
Input Range 3-Wire Input - 12 V dc, NAMUR Input - 8.2 V dc | ||
Output Range = 30 VDC or = 250 VAC | ||
Supply Voltage 10 → 30V dc | ||
Hazardous Area Certification Ex, SIL, UL | ||
Series IM(X)12 | ||
- COO (Country of Origin):
- DE
The Turck frequency transducer is equipped with intrinsically safe input circuits and issues a galvanically isolated transmission of frequency signals up to 20,000 Hz from the explosion-hazardous area to the safe area. This device is used for monitoring limit values. The device is suitable for use in Zone 2. A changeover relay is available on the output side. The device can be powered from a power bridge that also transmits a collective fault signal.
Input circuits monitored for wire break and short circuit
Parameterized via DIP/rotary coding switch
Complete galvanic isolation
Input reverse-polarity protected
Removable spring type terminals
Parameterized via DIP/rotary coding switch
Complete galvanic isolation
Input reverse-polarity protected
Removable spring type terminals
Related links
- Motrona Frequency Transducer Frequency Output, 11 … 30V dc Supply
- Phoenix Contact MINI MCR Series Frequency Transducer PWM Input 24V dc Supply
- Phoenix Contact MACX-MCR Series Frequency Transducer Current Output, 24V dc Supply