Wieland safeRELAY SNO 4063 Safety Relay 230V ac, Dual-Channel 3 Safety Contacts
- RS Stock No.:
- 512-7734
- Mfr. Part No.:
- R1.188.0980.0
- Brand:
- Wieland
Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£279.02
(exc. VAT)
£334.82
(inc. VAT)
- RS Stock No.:
- 512-7734
- Mfr. Part No.:
- R1.188.0980.0
- Brand:
- Wieland
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Wieland | |
Supply Voltage | 230V ac | |
Number of Channels | 2 | |
Safety Contacts | 3 | |
Function | Safety Switch/Interlock | |
Range | safeRELAY | |
Terminal Type | Screw | |
Depth | 114mm | |
Safety Category | 4 | |
Series | SNO 4063 | |
Width | 22.5mm | |
Performance Level | e | |
Length | 96.5mm | |
Select all | ||
---|---|---|
Brand Wieland | ||
Supply Voltage 230V ac | ||
Number of Channels 2 | ||
Safety Contacts 3 | ||
Function Safety Switch/Interlock | ||
Range safeRELAY | ||
Terminal Type Screw | ||
Depth 114mm | ||
Safety Category 4 | ||
Series SNO 4063 | ||
Width 22.5mm | ||
Performance Level e | ||
Length 96.5mm | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- DE
SNO 4063K Safety Relay for Emergency Stop & Guard DoorApplications
Can be used for emergency stop or guard door applications
Basic unit in accordance with EN 60204-1 and EN 954-1 for one or two-channel emergency stop monitoring
Safety category 4 pursuant to EN 954-1
Stop category 0 pursuant to EN 60204-1
Manual or automatic start
With / without cross circuit detection
Control loop for monitoring external contactors
3 enabling paths, N/O force guided
For processing signals of a light grid (OSSD compatible) pursuant to DIN EN 61496-1
LED displays for operating voltage, channel 1 and channel 2
Enclosure width 22.5 mm
Basic unit in accordance with EN 60204-1 and EN 954-1 for one or two-channel emergency stop monitoring
Safety category 4 pursuant to EN 954-1
Stop category 0 pursuant to EN 60204-1
Manual or automatic start
With / without cross circuit detection
Control loop for monitoring external contactors
3 enabling paths, N/O force guided
For processing signals of a light grid (OSSD compatible) pursuant to DIN EN 61496-1
LED displays for operating voltage, channel 1 and channel 2
Enclosure width 22.5 mm
Standards
EN 954-1, EN 60204-1, EN 61496-1
Approvals
CE, BG, GS, UL, CSA
Related links
- Wieland safeRELAY SNO 4083 Safety Relay 115 → 230V ac, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNO 4083 Safety Relay 24V dc, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNO 4003 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNA 4063K 1 Auxiliary Contacts Safety Relay 230V ac, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNA 4043K 1 Auxiliary Contacts Safety Relay 230V ac, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNO 4062 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 2 Safety Contacts
- Wieland safeRELAY SNO 4062KM 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 2 Safety Contacts
- Wieland safeRELAY SNO 1012 Safety Relay 24V ac/dc, Single Channel 2 Safety Contacts