Wieland safeRELAY SNO 4063 Safety Relay 230V ac, Dual-Channel 3 Safety Contacts
- RS Stock No.:
- 512-7734
- Mfr. Part No.:
- R1.188.0980.0
- Brand:
- Wieland
Discontinued
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£279.02
(exc. VAT)
£334.82
(inc. VAT)
- RS Stock No.:
- 512-7734
- Mfr. Part No.:
- R1.188.0980.0
- Brand:
- Wieland
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Wieland | |
| Supply Voltage | 230V ac | |
| Number of Channels | 2 | |
| Safety Contacts | 3 | |
| Function | Safety Switch/Interlock | |
| Range | safeRELAY | |
| Terminal Type | Screw | |
| Depth | 114mm | |
| Safety Category | 4 | |
| Width | 22.5mm | |
| Series | SNO 4063 | |
| Length | 96.5mm | |
| Performance Level | e | |
| Select all | ||
|---|---|---|
Brand Wieland | ||
Supply Voltage 230V ac | ||
Number of Channels 2 | ||
Safety Contacts 3 | ||
Function Safety Switch/Interlock | ||
Range safeRELAY | ||
Terminal Type Screw | ||
Depth 114mm | ||
Safety Category 4 | ||
Width 22.5mm | ||
Series SNO 4063 | ||
Length 96.5mm | ||
Performance Level e | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- DE
SNO 4063K Safety Relay for Emergency Stop & Guard DoorApplications
Can be used for emergency stop or guard door applications
Basic unit in accordance with EN 60204-1 and EN 954-1 for one or two-channel emergency stop monitoring
Safety category 4 pursuant to EN 954-1
Stop category 0 pursuant to EN 60204-1
Manual or automatic start
With / without cross circuit detection
Control loop for monitoring external contactors
3 enabling paths, N/O force guided
For processing signals of a light grid (OSSD compatible) pursuant to DIN EN 61496-1
LED displays for operating voltage, channel 1 and channel 2
Enclosure width 22.5 mm
Basic unit in accordance with EN 60204-1 and EN 954-1 for one or two-channel emergency stop monitoring
Safety category 4 pursuant to EN 954-1
Stop category 0 pursuant to EN 60204-1
Manual or automatic start
With / without cross circuit detection
Control loop for monitoring external contactors
3 enabling paths, N/O force guided
For processing signals of a light grid (OSSD compatible) pursuant to DIN EN 61496-1
LED displays for operating voltage, channel 1 and channel 2
Enclosure width 22.5 mm
Standards
EN 954-1, EN 60204-1, EN 61496-1
Approvals
CE, BG, GS, UL, CSA
Related links
- Wieland safeRELAY SNO 4083 Safety Relay 115 → 230V ac, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNO 4083 Safety Relay 24V dc, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNO 4003 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNA 4063K 1 Auxiliary Contacts Safety Relay 230V ac, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNA 4043K 1 Auxiliary Contacts Safety Relay 230V ac, Dual-Channel 3 Safety Contacts
- Wieland safeRELAY SNO 4062 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 2 Safety Contacts
- Wieland safeRELAY SNO 4062KM 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 2 Safety Contacts
- Wieland safeRELAY SNO 1012 Safety Relay 24V ac/dc, Single Channel 2 Safety Contacts