Allen Bradley Guardmaster Minotaur MSR8T 2 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 3 Safety Contacts
- RS Stock No.:
- 250-6421
- Mfr. Part No.:
- 440R-E23030
- Brand:
- Allen Bradley Guardmaster
Image representative of range
Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.
- RS Stock No.:
- 250-6421
- Mfr. Part No.:
- 440R-E23030
- Brand:
- Allen Bradley Guardmaster
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Allen Bradley Guardmaster | |
Supply Voltage | 24V ac/dc | |
Number of Channels | 1 | |
Safety Contacts | 3 | |
Function | Safety Switch/Interlock | |
Auxiliary Contacts | 2 | |
Range | Minotaur | |
Terminal Type | Screw | |
Depth | 45.5mm | |
Safety Category | 3 | |
Width | 73mm | |
Series | MSR8T | |
Length | 120mm | |
Select all | ||
---|---|---|
Brand Allen Bradley Guardmaster | ||
Supply Voltage 24V ac/dc | ||
Number of Channels 1 | ||
Safety Contacts 3 | ||
Function Safety Switch/Interlock | ||
Auxiliary Contacts 2 | ||
Range Minotaur | ||
Terminal Type Screw | ||
Depth 45.5mm | ||
Safety Category 3 | ||
Width 73mm | ||
Series MSR8T | ||
Length 120mm | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- GB
Minotaur MSR8T, Single Channel or Extension Unit
Ensures correct switching of up to 3 contactors with monitoring
Fail-safe internal monitoring
Single channel input for use with interlock switches and emergency stop buttons. 3 uncommitted safety output circuits and provides a contactor monitoring facility and auxiliary output for indication purposes
Power failure on safety critical internal faults result in a lock-out to a safe state
Can also be used as an extension unit for other devices. When inputs are connected to one of the outputs on the host unit, the MSR8T will mimic the outputs on the host unit
Fail-safe internal monitoring
Single channel input for use with interlock switches and emergency stop buttons. 3 uncommitted safety output circuits and provides a contactor monitoring facility and auxiliary output for indication purposes
Power failure on safety critical internal faults result in a lock-out to a safe state
Can also be used as an extension unit for other devices. When inputs are connected to one of the outputs on the host unit, the MSR8T will mimic the outputs on the host unit
Standards
EN 60204-1; EN 292; EN 954-1

Related links
- Allen Bradley Guardmaster Minotaur MSR11R 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 3 Safety Contacts
- Allen Bradley Guardmaster Minotaur MSR10RD 1 Auxiliary Contacts Safety Relay 24V ac/dc, Dual-Channel 8 Safety Contacts
- Allen Bradley Guardmaster MSR Dual-Channel 3
- Allen Bradley Guardmaster MSR Single Channel 3
- Allen Bradley Guardmaster MSR Single Channel 3
- Allen Bradley Guardmaster MSR Dual-Channel 3
- Allen Bradley 440R / MSR127TP 1 Auxiliary Contacts Safety Relay 24V ac/dc, Single Channel 3 Safety Contacts
- Allen Bradley Guardmaster MSR Single Channel 2 Safety Contacts