SICK TR4 Safety Switch, RFID Actuator Included, Valox
- RS Stock No.:
- 285-4392
- Mfr. Part No.:
- TR4-SDU02CB
- Brand:
- SICK
Subtotal (1 unit)*
£230.27
(exc. VAT)
£276.32
(inc. VAT)
FREE delivery for orders over £60.00
Stocked by manufacturer
- Ready to ship from 15 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £230.27 |
*price indicative
- RS Stock No.:
- 285-4392
- Mfr. Part No.:
- TR4-SDU02CB
- Brand:
- SICK
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | SICK | |
| Lock Style | RFID | |
| Product Type | Safety Switch | |
| Actuator Included | Yes | |
| Safety Contacts | 2 NO | |
| Housing Material | Valox | |
| Series | TR4 | |
| Switch Contact Current | 200mA | |
| Minimum Operating Temperature | -25°C | |
| IP Rating | IP67, IP69K | |
| Contact DC Voltage | 24V dc | |
| Contact AC Voltage | 230V ac | |
| Hazardous Area Certification | No | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | IEC 60529 | |
| Number of Head Directions | 5 | |
| Length | 88mm | |
| Depth | 20mm | |
| Width | 25mm | |
| Select all | ||
|---|---|---|
Brand SICK | ||
Lock Style RFID | ||
Product Type Safety Switch | ||
Actuator Included Yes | ||
Safety Contacts 2 NO | ||
Housing Material Valox | ||
Series TR4 | ||
Switch Contact Current 200mA | ||
Minimum Operating Temperature -25°C | ||
IP Rating IP67, IP69K | ||
Contact DC Voltage 24V dc | ||
Contact AC Voltage 230V ac | ||
Hazardous Area Certification No | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals IEC 60529 | ||
Number of Head Directions 5 | ||
Length 88mm | ||
Depth 20mm | ||
Width 25mm | ||
- COO (Country of Origin):
- DO
SICK TR4 Series Safety Switch, IP67, 24V Supply Voltage - TR4-SDU02CB
This safety switch is a non-contact RFID interlock designed to protect access points and guard doors in industrial automation. It provides two safety outputs with self-monitoring semiconductor technology and is intended for integration with safety controllers and Flexi Loop diagnostics. The unit operates from a 24V supply and is suited to harsh environments thanks to robust sealing and a Compact form.
Features and Benefits:
• RFID sensing ensures non-contact operation and reduced wear
• 2 safe outputs deliver safety-related signalling with self-monitoring
• Performance level PL e and SIL 3 enable use in high-risk applications
• IP69K ingress protection permits pressurised washdown environments
• Cable with M12 plug supports simple direct connection
• 2 safe outputs deliver safety-related signalling with self-monitoring
• Performance level PL e and SIL 3 enable use in high-risk applications
• IP69K ingress protection permits pressurised washdown environments
• Cable with M12 plug supports simple direct connection
Applications
• Suitable for machine guard door monitoring on production lines
• Used with safety controllers employing Flexi Loop diagnostics
• Ideal for food-industry equipment requiring washdown resistance
• Can be used for safeguarding access in robotics cells
• Used with safety controllers employing Flexi Loop diagnostics
• Ideal for food-industry equipment requiring washdown resistance
• Can be used for safeguarding access in robotics cells
What are the temperature operating limits?
It functions across an ambient range of -25°C to +70°C.
How is the switch connected electrically?
It uses a 0.2m cable with a 5-pin M12 plug and supports cables up to 200m.
What safety classifications does it meet?
It is rated Category 4 under EN ISO 13849 and SIL 3 per IEC 61508.
What mechanical stresses can it tolerate?
The device withstands vibration at 10Hz to 55Hz with 3.5mm amplitude and shock up to 30g, 11 ms.
Related links
- SICK TR4 Safety Switch Valox
- SICK TR4 Safety Interlock Switch Valox
- SICK Type 4 (En Iso 14119) Category 4 (EN ISO 13849) TR4 Safety Switch Valox
- SICK TR4 Safety Interlock Switch Vistal
- SICK STR1 Safety Interlock Switch Valox
- SICK STR1 Safety Switch Vistal
- SICK STR1 Safety Switch Vistal, Electronic
- SICK RE31 Safety Switch Fibreglass Reinforced Polyphenylene Sulphide, Magnet