Omron, A4EG Series Holding Key

Subtotal (1 unit)*

£77.87

(exc. VAT)

£93.44

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • 8 unit(s) shipping from 25 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£77.87

*price indicative

RS Stock No.:
215-5019
Mfr. Part No.:
A4EG-OP3
Brand:
Omron
Find similar products by selecting one or more attributes.
Select all

Brand

Omron

Accessory Type

Holding Key

Product Type

Safety Enabling Switch Component

Series

A4EG

Omron A4EG Series Safety Enabling Switch Component, Holding Key - A4EG-OP3


This safety enabling switch component is an optional holding key accessory designed to work with enabling grip switches in industrial safety circuits. It enables mode selection and secure holding of the enabling function when used alongside safety-door switches and related control modules. The device is intended for indoor machine applications where controlled manual operation and maintenance-mode interlock are required.

Features & Benefits


• Holding key designed for vertical insertion with secure mounting
• Mounting screws tightened to 0.5–0.7 N·m prevent loosening
• Uses supplied spring washers and screws for stable installation
• Prevents operation when inserted in door switch, enhancing safety
• Compatible with conduit connector and common gland for cabling
• Compact accessory allowing manual mode selection during maintenance

Applications


• Suitable for use with safety-door switches to enable maintenance mode
• Ideal for integration with logical AND safety guarding units
• Used with enabling grip switches to select operator-held mode
• Can be used where removable interlock holding is required during servicing

How should I mount the accessory to avoid loosening during operation?


Fit the two supplied mounting screws with the provided spring washers and tighten to the specified torque of 0.5–0.7 N·m

using adhesive on the threads is recommended to resist vibrational loosening.

Can the key be used while the machine is running to bypass safety functions?


The accessory must not be used to override safety

circuits should be arranged so machinery cannot operate when the holding key is inserted in the door switch.

What precautions apply to handling and installation?


Avoid applying excessive force to the tip, do not drop the key, and stop use if deformity or breakage occurs

only use the specified D4NS door switch mounting orientation.

What cable requirements and sealing details must I observe when fitting nearby cabling?


Use multi-core cable AWG20–18 (0.5–0.75 mm2) and a cable diameter of 8.0–13 mm with the correct conduit connector assembly to maintain seal performance.

Related links