UE410 Series Safety Controller, 30 V dc

  • RS Stock No. 701-9171
  • Mfr. Part No. UE410-MM3
  • Brand Sick
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

UE410-MM3 Muting Main Unit and UE410-XM3 Muting Extension

Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches

2 or 4 muting sensors
1 reset/restart input and external device monitoring
Activation and time adjustable 0.33 to 60 min
Type of output safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored
Maximum output current: 2A
Maximum response time: 13 ms
Maximum switch on time: 10 s
Maximum power consumption: 3 W
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)

Specifications
Attribute Value
Series UE410
Supply Voltage 30 V dc
Width 22.5mm
Depth 120.8mm
Length 96.5mm
6 In stock for FREE next working day delivery
Price Each
£ 229.60
(exc. VAT)
£ 275.52
(inc. VAT)
Units
Per unit
1 +
£229.60
Related Products
Configurable device capable of centralised monitoring of multiple ...
Description:
Configurable device capable of centralised monitoring of multiple safety functions such as E-stops, safety interlocks, magnetic safety interlocks, two hand controllers, light curtains, zero speed detection, enabling switches. Designed to provide a solution for safety applications requiring conformity to category 4 of standard EN 954-1/ISO 13849-1 and SIL 3 requirements ...
This is the main module in the UE410 ...
Description:
This is the main module in the UE410 FLEXI system. 8 available programs can be set using rotary switches (e.g. emergency stop pushbuttons, Type IIIA and IIIC two-hand controls, safety interlock switches, non-contact switches, testable Type 2 sensors, hold to run switches, safety light curtains and safety light grids, safety ...
One system covers both safety-related (E-stop, light curtain ...
Description:
One system covers both safety-related (E-stop, light curtain etc) and standard control functions Economical non-expandable solution Simple wiring means short commissioning times Simple intuitive programming resulting in time and cost saving Flexible to apply, as only one solution required for applications up to Category 4 (EN954-1) and applications up to ...
The MSR42 multi-function safety relay is the control ...
Description:
The MSR42 multi-function safety relay is the control module for the Guard Shield Micro 400 safety light curtain, but can also be used with any light curtain. This versatile Category 4 safety device has a pair of PNP solid state, 400 mA OSSDs for direct connection to the final switching ...