Kopp 2P 16 A Instantaneous RCD Switch, Trip Sensitivity 30mA

  • RS Stock No. 239-4896
  • Mfr. Part No. 7516.2801.4
  • Brand Kopp
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Residual circuit-breaker, 2 and 4-pole

This 2 / 4-pole RCD meets DIN VDE 0664 Part 1. It records AC and pulsating DC.
Test symbols: VDE; ÖVE; SEV; CEBEC; SEMKO; NEMKO; DEMKO; FIMKO; KEMA.
Un = 230 Vac with 2-pole,
Un = 230 Vac / 400 Vac with 4-pole.

Kopp — residual circuit-breaker

Highest Precision

The measuring equipment fitted with a summation current transformer handles AC and pulsed DC fault currents and is not sensitive to surge currents → 250 A (pulse design 8//20, DIN VDE 0432 part 2).
In accordance with DIN VDE 0664 part 1, in the event of a failure the equipment switches off within 0.2 sec.

Convenient mounting
The patented quick fix feature of the KOPP MCB is also used in this protection circuit series. This makes it easy to lock them into the DIN rail and also remove them from the connection if required.

Clear detection of the switch-off source
As was the case with the MCB, even the switch-off source for residual circuit-breakers can be detected from the lever position. If the lever is in the "OFF" position, the switch-off was manual and intentional. If, on the other hand, it is in the "RESET" position the device was switched off by a residual current in the system.

Sophisticated wiring technology
On delivery, the terminals are already opened and you have the option to cross-wire the devices with the commoning bar - all helping you save on installation time and therefore cost.

Specifications
Attribute Value
Number of Poles 2
Current Rating 16 A
Trip Sensitivity 30mA
Rated AC Voltage 230 V
Mounting Style DIN Rail
Break Time Instantaneous
7 in stock for FREE next working day delivery
18 available from Europe for delivery within 1 working day(s)
Price Each
£ 57.50
(exc. VAT)
£ 69.00
(inc. VAT)
Units
Per unit
1 - 4
£57.50
5 +
£54.57
Related Products
Combined SMISSLINE RCCBB or C characteristic Free selection ...
Description:
Combined SMISSLINE RCCBB or C characteristic Free selection and display of the contacting phase Sensitive to AC and pulsed DC fault currents With integrated input wiring Pole conductor display Contact position display Pluggable in any position Double-level output terminal.
From Siemens the 5SV3 series are RCCBs suitable ...
Description:
From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality. Residual current operated circuit breaker for personnel and fire protection Silicone free2 or 4 ...
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units. Manufactured to BS EN 6100830 and 100mA trip options2 and 4 pole options (@30m A).
RCDs that allow the use of HX³ supply ...
Description:
RCDs that allow the use of HX³ supply busbars. Residual current devices from 6 A to 32 AAC type : detect AC component faults.