ABB RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, System Pro M Compact Range
- RS Stock No.:
- 201-6930
- Distrelec Article No.:
- 300-76-709
- Mfr. Part No.:
- 2CSR255180R1165 DS201 B16 A30
- Brand:
- ABB
Subtotal (1 unit)*
£166.85
(exc. VAT)
£200.22
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 47 unit(s) ready to ship
- Plus 13 unit(s) ready to ship from another location
- Plus 999,999,952 unit(s) shipping from 24 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £166.85 |
*price indicative
- RS Stock No.:
- 201-6930
- Distrelec Article No.:
- 300-76-709
- Mfr. Part No.:
- 2CSR255180R1165 DS201 B16 A30
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | ABB | |
Current Rating | 16A | |
Number of Poles | 2 | |
Range | System Pro M Compact | |
Series | DS201 | |
Trip Sensitivity | 30mA | |
Circuit Breaker Type | RCBO | |
Tripping Characteristics | Type B | |
Rated AC Voltage | 240V | |
Mounting Style | DIN Rail Mount | |
Breaking Capacity at Maximum Voltage Rating | 10 kA | |
Overall Depth | 69mm | |
Overall Width | 35mm | |
Terminal Contact Type | Screw | |
Reset Actuator Type | Toggle Switch | |
Overall Length | 69mm | |
Break Time | Instantaneous | |
Special Features | Short Circuit Protection | |
Select all | ||
---|---|---|
Brand ABB | ||
Current Rating 16A | ||
Number of Poles 2 | ||
Range System Pro M Compact | ||
Series DS201 | ||
Trip Sensitivity 30mA | ||
Circuit Breaker Type RCBO | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 240V | ||
Mounting Style DIN Rail Mount | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Depth 69mm | ||
Overall Width 35mm | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Toggle Switch | ||
Overall Length 69mm | ||
Break Time Instantaneous | ||
Special Features Short Circuit Protection | ||
- COO (Country of Origin):
- IT
ABB DS201 Series RCBO, 16A Current Rating, 30mA Trip Sensitivity - 2CSR255180R1165 DS201 B16 A30
This RCBO is designed to offer both overload and short-circuit protection in single-phase electrical circuits. With its 2-pole configuration, this compact device integrates seamlessly into your setup, ensuring robust electrical safety. It features dimensions of 69mm x 35mm x 69mm, making it suitable for installation on a DIN rail without taking up excessive space.
Features & Benefits
• Provides short circuit protection to enhance safety
• 30 mA trip sensitivity protects against earth faults
• High breaking capacity of up to 10kA for reliable performance
• Type B design safeguards against sinusoidal and direct currents
• Toggle switch reset actuator for easy operation
• Suited for use in various applications with a DIN rail mount
• 30 mA trip sensitivity protects against earth faults
• High breaking capacity of up to 10kA for reliable performance
• Type B design safeguards against sinusoidal and direct currents
• Toggle switch reset actuator for easy operation
• Suited for use in various applications with a DIN rail mount
Applications
• Used for protecting single-phase circuits in residential settings
• Ideal for automation systems to prevent electrical faults
• Utilised in commercial buildings for enhanced electrical safety
• Suitable for equipment requiring short-circuit and overload protection
• Ideal for automation systems to prevent electrical faults
• Utilised in commercial buildings for enhanced electrical safety
• Suitable for equipment requiring short-circuit and overload protection
What are the advantages of the toggle switch reset actuator?
The toggle switch reset actuator allows for straightforward manual intervention, making it easier to reset the device after a trip, thereby simplifying maintenance and reducing downtime.
How does the 30 mA trip sensitivity enhance user safety?
With a 30 mA trip sensitivity, the device quickly disconnects the circuit in the event of an earth fault, significantly reducing the risk of electric shock and potential injuries.
In what environmental conditions can this product operate effectively?
It operates efficiently in ambient temperatures ranging from -25°C to 55°C, catering to a broad spectrum of industrial and commercial environments.
What is the significance of the high breaking capacity?
The 10kA breaking capacity ensures that in the event of a fault, the device can safely interrupt the current flow, minimising damage to the electrical system and maintaining overall safety.
Related links
- ABB RCBO 2P Poles Type B, System Pro M Compact Range
- ABB RCBO 2P Poles System Pro M Compact Range
- ABB RCBO 2P Poles Type A, System Pro M Compact Range
- ABB RCBO 2P Poles Type C, System Pro M Compact Range
- ABB RCBO 1P+N Poles Type B, System Pro M Compact Range
- ABB RCBO 2P Poles Type B, System Pro M Compact Range
- ABB RCBO 2P Poles, 30mA Trip Sensitivity
- ABB RCBO 2P Poles System Pro M Compact Range