Telemecanique Sensors Pressure Sensor, 0.6bar Min, 10bar Max, Relay Output, Differential Reading
- RS Stock No.:
- 302-5838
- Distrelec Article No.:
- 303-99-957
- Mfr. Part No.:
- XMLA010A2S11
- Brand:
- Telemecanique Sensors
Subtotal (1 unit)*
£159.78
(exc. VAT)
£191.74
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 12 unit(s) ready to ship
- Plus 51 unit(s) ready to ship from another location
- Plus 13 unit(s) shipping from 04 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £159.78 |
*price indicative
- RS Stock No.:
- 302-5838
- Distrelec Article No.:
- 303-99-957
- Mfr. Part No.:
- XMLA010A2S11
- Brand:
- Telemecanique Sensors
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Telemecanique Sensors | |
Pressure Reading Type | Differential | |
Minimum Pressure Reading | 0.6bar | |
Maximum Pressure Reading | 10bar | |
Accuracy | 2 % | |
Output Type | Relay | |
Media Measured | Air, Fresh Water, Hydraulic Fluid, Sea Water | |
Process Connection | G1/4 | |
Electrical Connection | PG13.5 Cable Gland | |
Maximum Current | 3 A ac, 100 mA dc | |
Supply Voltage | 120 → 240 V ac, 250 V dc | |
Housing Material | Zinc Alloy | |
IP Rating | IP66 | |
Minimum Operating Temperature | -25°C | |
Maximum Operating Temperature | +70°C | |
Select all | ||
---|---|---|
Brand Telemecanique Sensors | ||
Pressure Reading Type Differential | ||
Minimum Pressure Reading 0.6bar | ||
Maximum Pressure Reading 10bar | ||
Accuracy 2 % | ||
Output Type Relay | ||
Media Measured Air, Fresh Water, Hydraulic Fluid, Sea Water | ||
Process Connection G1/4 | ||
Electrical Connection PG13.5 Cable Gland | ||
Maximum Current 3 A ac, 100 mA dc | ||
Supply Voltage 120 → 240 V ac, 250 V dc | ||
Housing Material Zinc Alloy | ||
IP Rating IP66 | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature +70°C | ||
RoHS Status: Exempt
OsiSense XMLA Pressure Switches
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are for detection of a single threshold.
Fixed differential
External pressure setting window available
1 NO & 1 NC snap acting contacts
Temperature range: –25 to +70 °C
Enclosure rating: IP65 with plug-in connector, IP66 with terminal connections
Operating rate: up to 120 operations / min. for diaphragm and 60 / min. for piston
Media connection: 1/4" NPT
Conduit connection: 1/2" NPT
External pressure setting window available
1 NO & 1 NC snap acting contacts
Temperature range: –25 to +70 °C
Enclosure rating: IP65 with plug-in connector, IP66 with terminal connections
Operating rate: up to 120 operations / min. for diaphragm and 60 / min. for piston
Media connection: 1/4" NPT
Conduit connection: 1/2" NPT
Note
Pressure quoted is 'per cycle' and (occasional)
Telemecanique Sensors Pressure Sensor, Differential Reading Type, G1/4 Process Connection - XMLA Series - XMLA010A2S11
Ramp up efficiency in your processes with this pressure sensor from Telemecanique Sensors. You can use it to measure and control the pressure of many fluids and gases, from fresh water, sea water and steam to air, hydraulic oils and corrosive substances. The sensor uses differential pressure readings from two points in your system to give you a heads-up when the pressure or flow rate drops. Its zinc alloy housing is hardwearing and resistant to corrosion, so you can be sure of a long lifespan.
Features & Benefits
• Broad range of pressure readings between 0.6 bar and 10 bar for versatility
• Readings accurate to 2% off actual values, giving you a precise picture
• PG13.5 cable gland electrical connection and G1/4 process connection for simple installation
• Readings accurate to 2% off actual values, giving you a precise picture
• PG13.5 cable gland electrical connection and G1/4 process connection for simple installation
Applications
• Industrial automation
• Energy production
• Automotive manufacture
• Energy production
• Automotive manufacture
Can I use this pressure sensor in extreme temperatures?
Yes – this pressure sensor has a broad operating temperature range between -25°C and +70°C, so it's ideal for harsh environments.
Is this unit suitable for washing down?
An IP66 rating with terminal connections means the unit's protected against powerful jets of water. It's also completely shielded from dust.
Related links
- Telemecanique Sensors Pressure Sensor 10bar Max Differential Reading
- Telemecanique Sensors Pressure Sensor 10bar Max Differential Reading
- Burkert Type 1045 Series Pressure Sensor 10bar Max Differential Reading
- Telemecanique Sensors Pressure Sensor 160bar Max Differential Reading
- Telemecanique Sensors Pressure Sensor 4bar Max Differential Reading
- Telemecanique Sensors Pressure Sensor 70bar Max Differential Reading
- Telemecanique Sensors Pressure Sensor 4bar Max Differential Reading
- Telemecanique Sensors Pressure Sensor 20bar Max Differential Reading