Fluke 718 -850 mbar to 20 bar Pressure Calibrator, RSCAL
- RS Stock No.:
- 192-5835
- Mfr. Part No.:
- FLUKE-718 300G
- Brand:
- Fluke
Subtotal (1 unit)*
£3,900.00
(exc. VAT)
£4,680.00
(inc. VAT)
FREE delivery for orders over £60.00
Temporarily out of stock
- 4 unit(s) shipping from 22 May 2026
- Plus 3 unit(s) shipping from 03 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £3,900.00 |
*price indicative
- RS Stock No.:
- 192-5835
- Mfr. Part No.:
- FLUKE-718 300G
- Brand:
- Fluke
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Battery Type | Alkaline | |
| Product Type | Pressure Calibrator | |
| Maximum Pressure Measurement | 20bar | |
| Minimum Pressure Measurement | -850mbar | |
| Accuracy | ±0.025 % | |
| Resolution | 1 mbar | |
| Model Number | 718 | |
| Data Logging | No | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Maximum Operating Temperature | 55°C | |
| Length | 216mm | |
| Standards/Approvals | No | |
| Height | 66mm | |
| Width | 94mm | |
| Hazardous Area Certification | NO | |
| Calibrated | RSCAL | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Battery Type Alkaline | ||
Product Type Pressure Calibrator | ||
Maximum Pressure Measurement 20bar | ||
Minimum Pressure Measurement -850mbar | ||
Accuracy ±0.025 % | ||
Resolution 1 mbar | ||
Model Number 718 | ||
Data Logging No | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Maximum Operating Temperature 55°C | ||
Length 216mm | ||
Standards/Approvals No | ||
Height 66mm | ||
Width 94mm | ||
Hazardous Area Certification NO | ||
Calibrated RSCAL | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Pressure Calibrator, 20 Bar Maximum Pressure Measurement, ±0.025% Accuracy - FLUKE-718 300G
This pressure calibrator provides a compact, portable solution for pressure source generation and milliamp measurement to support calibration and maintenance of transmitters, gauges and switches in industrial settings. It combines a user-facing LCD for simultaneous pressure and current readouts with a protected pneumatic pump design that can be cleaned and serviced in the field, making it suitable for on-site calibration tasks across automation and electrical disciplines.
Features & Benefits
• ±0.025% accuracy improves measurement confidence for calibration tasks
• 1 mbar resolution allows fine pressure discrimination during tests
• Maximum measurement 20 bar supports higher-pressure device verification
• Minimum measurement −850 mbar enables vacuum and low-pressure checks
• Battery powered with 20 h life reduces interruptions on site
• Current loop measurement capability simplifies transmitter loop diagnostics
• 1 mbar resolution allows fine pressure discrimination during tests
• Maximum measurement 20 bar supports higher-pressure device verification
• Minimum measurement −850 mbar enables vacuum and low-pressure checks
• Battery powered with 20 h life reduces interruptions on site
• Current loop measurement capability simplifies transmitter loop diagnostics
**Applications**
• Suitable for calibrating industrial pressure transmitters and transmitters loops
• Ideal for pressure switch testing in control panels and process skids
• Used with gauges for field verification and routine maintenance
• Can be used for commissioning and troubleshooting pneumatic control systems
• Suitable for low-pressure and vacuum system checks in laboratory setups
• Ideal for pressure switch testing in control panels and process skids
• Used with gauges for field verification and routine maintenance
• Can be used for commissioning and troubleshooting pneumatic control systems
• Suitable for low-pressure and vacuum system checks in laboratory setups
What power arrangement does it use for field operation?
It runs from alkaline batteries and provides typical runtime up to 20 h depending on functions used.
How does the pump cope with accidental fluid exposure?
The pump includes protective check valves and a serviceable valve assembly that can be cleaned in situ using isopropyl alcohol and simple tools.
What display information is presented simultaneously?
The LCD shows a five-digit pressure Value together with current measurement for concurrent pressure and loop diagnostics.
What environmental limits should I observe during use?
The operating temperature range is −10°C to 55°C with defined humidity tolerances that reduce at higher temperatures.
How portable is the instrument for site engineers?
The unit weighs 992 g, providing a Compact and lightweight instrument for routine field work.
Standards
CSA C22.2 no. 1010.1: 1992, IEC 61010, CAT I 30V
Supplied with
Fluke 718, holster, TL75 test leads, AC72 crocodile clips, two 9 V batteries, instruction manual
Related links
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator
- Fluke 718 -850 mbar to 6.895 bar Pressure Calibrator
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20.68 bar Pressure Calibrator
- Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 20 bar Pressure Calibrator
- Fluke 718 -850mbar to 7bar Pressure Calibrator