Norgren Roller Lever 3/2 Mechanical Valve 302 Series, G 1/8, 1/8, III B

Bulk discount available

Subtotal (1 unit)*

£117.64

(exc. VAT)

£141.17

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 3 unit(s) ready to ship
  • Plus 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 - 4£117.64
5 - 9£115.30
10 +£112.94

*price indicative

RS Stock No.:
217-9981
Mfr. Part No.:
03029302
Brand:
Norgren
Find similar products by selecting one or more attributes.
Select all

Brand

Norgren

Control Mechanism

Roller Lever

Connection Port Thread

G 1/8

Function

3/2

Thread Size

1/8

Thread Standard

G

Manufacturer Series

302

Maximum Operating Pressure

10 bar

Body Material

PA

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+70°C

Model Number p

III B

RoHS Status: Exempt

COO (Country of Origin):
CZ

IMI Norgren Roller-Lever Mechanical Valve, 3/2 Function, 1/8 Thread - 302 Series - 03029302


Use this roller-lever mechanical valve from IMI Norgren to control airflow in your pneumatic system. It has three ports in two positions that you can drive manually or mechanically using its actuated spool valve. The valve can supply airflow in either direction for versatile use. Its PA6 (polyamide 6) body material is lightweight at 0.12kg, so you can be sure the unit won't put any strain on connected tubing. This high-performance material resists abrasion and impact, as well as moisture and chemical corrosion, making this valve a durable option.

Features & Benefits


• Attaches to a pneumatic system with the through-hole method for a reliable connection
• G1/8 threaded end screws in place for a secure fit
• Maximum operating pressure of 10 bar or 145psi (pounds per square inch) for high flow capacity

Applications


• Chemical plants
• Medical facilities
• Factory automation
• Marine engines

How does the roller-level mechanism operate?


The roller-level mechanism has a cam that rotates to move the lever up and down. When the cam makes contact with the valve, it causes it to open or close.