Festo Magneto Resistive Pneumatic Position Detector, IP65, IP68, IP69K, 24V dc, NC Operation, SMT-8, with LED

Bulk discount available

Subtotal (1 unit)*

£40.15

(exc. VAT)

£48.18

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 28 unit(s) ready to ship
  • Plus 10 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 - 4£40.15
5 - 9£38.52
10 +£36.95

*price indicative

RS Stock No.:
121-5834
Mfr. Part No.:
SMT-8M-A-PO-24V-E-7,5-OE
Brand:
Festo
Find similar products by selecting one or more attributes.
Select all

Brand

Festo

Type

Magneto Resistive

Supply Voltage

24V dc

Manufacturer Series

SMT-8

LED Indicator

Yes

Operation

NC

Compatible With

T-Slot

IP Rating

IP65, IP68, IP69K

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+85°C

Model Number p

574340

Outlet Port - Connection Type

Plug In

COO (Country of Origin):
TR

Festo Pneumatic Position Detector, For Use with T-Slot Cylinders, 24V DC Supply Voltage - SMT-8M-A-PO-24V-E-7,5-OE


Achieve pinpoint precision with this pneumatic position detector from Festo. It's designed to detect the presence and proximity of workpieces, even in busy setups. Since it's a magnetoresistive sensor, the unit accurately detects even small changes in magnetic fields, ensuring your measurements are on the money. Fast turn-on and turn-off times of 1.3ms and 1.4ms reduce downtime and boost efficiency. The unit's PA-reinforced high alloy steel housing protects against impact and corrosion, so it stands the test of time.

Features & Benefits


• LED indicators provide quick and contactless status monitoring
• IP68 rating indicates resistance to water immersion up to 1.5m for 30 minutes
• Performs in temperatures between -40°C and +85°C, so it's an ideal choice for industrial settings

Applications


• Wind turbines
• HVAC systems
• Material handling

How long is this detector's cable?


You can rely on the unit to go the extra mile, as it comes with a 7.5m cable to give you plenty of reach.

How do I mount this detector?


Simply insert this unit into a compatible cylinder's T-slot from above, and you're ready to go.