Siemens LOGO! Series I/O module for Use with LOGO! 8, LOGO! 8.2, 24 V dc Supply, Analogue Output

Subtotal (1 unit)*

£123.22

(exc. VAT)

£147.86

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 13 unit(s) ready to ship
  • Plus 66 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£123.22

*price indicative

RS Stock No.:
825-1691
Distrelec Article No.:
110-95-457
Mfr. Part No.:
6ED1055-1MM00-0BA2
Brand:
Siemens
Find similar products by selecting one or more attributes.
Select all

Brand

Siemens

Manufacturer Series

LOGO!

Output Type

Analogue

For Use With

LOGO! 8, LOGO! 8.2

Supply Voltage

24 V dc

Number of Outputs

2

Mounting Type

DIN Rail

Output Current

300 mA

Maximum Operating Temperature

+55°C

Programming Interface

Computer

Minimum Operating Temperature

0°C

Depth

58mm

Standards Met

CE, CSA, FM

Dimensions

90 x 35.5 x 58 mm

Width

35.5mm

Number of Analogue Outputs

2

Length

90mm

COO (Country of Origin):
CN

Siemens I/O Module For Use With LOGO! 8 And LOGO 8.2 Series, 2 Analogue Outputs - 6ED1055-1MM00-0BA2


Use this I/O expansion module from Siemens to transmit operating signals from a field device to a programmable logic controller. It features 2 analogue outputs, meaning it's suitable for monitoring analogue signals of the connected device such as the voltage and current rating. For versatility, the unit has a broad voltage output range between 0 and 10V, as well as a current output range between 4 and 20mA. It uses a computer programming interface for ease of connection to your control system. Thanks to the interactive drag-and-drop setup of its companion LOGO! Soft Comfort V8.1 software (825-1704), it's simple to configure. This module is compatible with logic modules from the LOGO! 8 and LOGO! 8.2 series.

• Wide operating temperature range between 0°C and +55°C to withstand harsh environments
• Compact dimensions of 90 (L) x 35.5 (W) x 58mm (D) to fit in tight spaces

How do I mount this expansion module?


You can mount this module by clipping it to a DIN rail without the need for any specialist tools.

Why do I need an expansion module?


An expansion module lets you connect additional machine sensors to your PLC without modifying the entire system.

Related links