Schneider Electric Twido Logic Module, 24 V dc Relay, Transistor, 24 x Input, 14 x Output With Display

Currently unavailable
We don’t know if this item will be back in stock, it is being discontinued by the manufacturer.
RS Stock No.:
548-050
Mfr. Part No.:
TWDLCDE40DRF
Brand:
Schneider Electric
Find similar products by selecting one or more attributes.
Select all

Brand

Schneider Electric

Manufacturer Series

Twido

Number of Inputs

24

Output Type

Relay, Transistor

Supply Voltage

24 V dc

Input Type

Sink/Source

Number of Outputs

14

Network Type

Ethernet

Maximum Operating Temperature

+50°C

Output Current

2 A

Number of Communication Ports

1

Programming Language Used

Ladder Logic

Mounting Type

DIN Rail

Depth

70mm

Program Capacity

3000 Instructions

Display Included

Yes

Communication Port Type

RS485

Dimensions

90 x 157 x 70 mm

Minimum Operating Temperature

0°C

Programming Interface

Computer, HMI

Length

90mm

Width

157mm

COO (Country of Origin):
CN

Twido Compact Controller


24 Vdc inputs
Isolated outputs
100base-TX ethernet via RJ45
Output rating for relay outputs: 2A@ 250Vac
Output rating for transistor outputs: 0.3A@ 24Vdc
Dimensions: H90 x W80 x D70mm (10 and 16 I/O)
H90 x W95 x D70mm (24 I/O)
H90 x W157 x D70mm (40 I/O)


Schneider Electric Twido Base Units - Additional Info:


Twido programmable controller from Telemecanique providing flexible automation solutions for the control systems. Designed to be user-friendly and flexible, with powerful control functions.


Small footprint reduces panel size for applications where space is limited
Flexible cabling choices (removable screw terminal blocks and spring-type connectors for expandable units), allowing quick and easy wiring
Suitable for applications requiring 10 - 264 I/O points
Compact controllers available with 10, 16, 24 or 40 I/O points
Each controller has an RS-485 programming port and stock no. 528-8643 also has an RJ45 ethernet port
Modular controllers available with 20 or 40 I/O points
All products in the Twido range meet the standards of the following regulatory agencies: IEC61131-2, UL1604/CSA C22.2 No.213 (class 1, division 2, groups A, B, C, D), CE and TÜV


Maximum I/O configuration


In order to connect all digital Input/Output modules and analogue Input/Output modules to base controllers, units should be built on DIN rails starting from the right-hand side of the bases, according to the following rules:


10 and 16 I/O compact bases cannot be expanded
24 I/O compact bases, can accommodate up to a maximum of 4 modules
40 I/O compact bases, can accommodate up to a maximum of 7 modules
20 I/O modular bases, can accommodate up to a maximum of 4 modules
40 I/O modular bases, can accommodate up to a maximum of 7 modules