Siemens Base for Use with ET 200SP

Subtotal (1 unit)*

£23.23

(exc. VAT)

£27.88

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 4 unit(s) ready to ship
  • Plus 46 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£23.23

*price indicative

RS Stock No.:
203-4172
Mfr. Part No.:
6ES7193-6BP20-0BF0
Brand:
Siemens
Find similar products by selecting one or more attributes.
Select all

Brand

Siemens

Accessory Type

Base Unit

Range

SIMATIC

For Use With

ET 200SP

Termination

Push-In

Maximum Operating Temperature

+60°C

Dimensions

20 x 117 x 35 mm

COO (Country of Origin):
DE

Siemens SIMATIC Series Base, 60°C Maximum Operating Temperature, Push-In Termination - 6ES7193-6BP20-0BF0


This base unit is an essential accessory within the SIMATIC range, specifically designed for use with the ET 200SP system. Measuring 20mm in width, 117mm in height, and 35mm in depth, this compact base module supports efficient installation within industrial automation environments. Its design incorporates push-in termination technology, which streamlines connection processes and enhances reliability.

Features & Benefits


• Enables quick connection with push-in terminal design
• Ensures excellent isolation between supply voltages
• Integrated support for automatic slot encoding
• Compact dimensions facilitate integration within limited spaces

Applications


• Used as a base accessory for modular automation systems
• Ideal for configuring Siemens automation equipment
• Suitable for horisontal and vertical installation settings
• Integrates seamlessly with other industrial automation components

What current carrying capacity can be expected from this unit?


The base unit supports a maximum current carrying capacity of 10A for both the P1 and P2 bus, ensuring reliable performance under operational stress.

How does the push-in terminal design enhance usability?


The push-in terminal design simplifies connection processes, allowing for faster installation and reduced wiring time in various applications.

What are the operational temperature limits for this unit?


It can operate within a temperature range from -30°C to +60°C, making it adaptable to various industrial environments.

Is there a limit on installation altitude for optimal performance?


Yes, it is designed for installation at altitudes up to 2,000m above sea level, with provisions available for greater altitudes upon request.

How does the unit provide electrical isolation?


The design ensures electrical isolation between the backplane bus and supply voltages, as well as among power and process terminals, enhancing safety in electrical configurations.