Tektronix P5100A Oscilloscope Probe, Probe Type: Passive 500MHz 1kV 1:100

  • RS Stock No. 734-5013
  • Mfr. Part No. P5100A
  • Brand Tektronix
Technical Reference
Legislation and Compliance
RoHS Status: Exempt
COO (Country of Origin): CN
Product Details

Tektronix P5100A Passive High Voltage Probe

The P5100A is a low input capacitance high-voltage (2.5 kV) probe designed for higher-frequency applications. The probe can be compensated to match plug-ins and oscilloscopes with nominal input capacitances of 7 → 30 pF. A variety of screw-on accessories provides easy connection to the device-under-test. Applications include power supply design, design motor drive, electronic ballast, power semiconductors, switch mode control, UPS systems and power converters.

2500 VPeak 1000 V CAT II
100X with readout coding

Approvals

UL3111-1, EN61010-1, IEC61010-2-031, CSA1010.1, CSA1010.2.031

Supplied with

Cable markers set, crocodile clip, adjustment tool, hooktip (small), hooktip (large), 18in ground lead, 6in ground lead, instruction manual (070-8151-04)

Tektronix Oscilloscope Probes

The Tektronix oscilloscope high voltage probe has a low input capacitance designed for higher frequency applications. This probe can be compensated to match plug-ins and oscilloscopes with nominal input capacitances of 7pF to 30pF. A variety of screw-on accessories provide an easy connection to the device under test.

Supplied with:
• Cable markers set
• Crocodile clip
• Adjustment tool
• Hooktip (small)
• Hooktip (large)
• 18in ground lead
• 6in ground lead
• Instruction manual

Features and Benefits

• Bandwidth is DC to 500MHz
• Attenuation ratio is 1:100
• Input impedance is 40Mohmll2.5pF
• Rise time is <700ps
• Maximum common mode input voltage is ±1KV
• Maximum input voltage DC or RMS is 2.5kVPeak 1000VRMS CAT II
• Wide compensation range (7pF to 30pF)

Applications

• Power supply design
• Design motor drive
• Electronic ballast
• Power semiconductors
• Switch mode control
• UPS systems
• Power converters

Certifications

• UL3111-1
• EN61010-1
• IEC61010-2-031
• CSA1010.1
• CSA1010.2.031
• CAT II 1000VAC

Specifications
Attribute Value
Probe Type Passive
Attenuation 1:100
Bandwidth 500MHz
Maximum Common Mode Input Voltage 1kV
Model Number p P5100A
Safety Category Level CAT II
Safety Category Voltage 1000V ac
Series 5000
Safety Category CAT II 1000 V ac
Rise Time 700ps
9 In stock for FREE next working day delivery
Price Each
£ 492.00
(exc. VAT)
£ 590.40
(inc. VAT)
Units
Per unit
1 +
£492.00
Related Products
Bandwidth 500 MHz Probe Ratio 10:1Cable Length 1.2 ...
Description:
Bandwidth 500 MHz Probe Ratio 10:1Cable Length 1.2 meters Input Impedance 10 MOhm Capacitance 12 p FApprox. Rise Time 3 ns Max. Voltage 1000 V CAT III / 600 V CAT IVCompensation Range 10 to 22 p FSafety Rating 1000 V CAT III / 600 V CAT IVChoice of colours: ...
This unique probe is designed with two eight-channel ...
Description:
This unique probe is designed with two eight-channel pods and simplifies the process of connecting to the DUT. The P6316 can connect directly to 8x2 square pin headers spaced on tenth-of-an-inch centres. When more attachment flexibility is required, the included flying lead sets and grabbers can be clipped on to ...
Solves three longstanding problems by providing: lower DUT ...
Description:
Solves three longstanding problems by providing: lower DUT loading (≤1 pF/1 MΩ probe loading); direct and easy access to SMDs; accesses DUT signals and scope bandwidth for TDS600/700/3000/5000/6000/7000*1 and CSA7000 scopes up to 1 GHz bandwidths. Provides the electrical and mechanical performance required for today's digital systems designs. No additional ...
For design, validation, debugging and characterization of common ...
Description:
For design, validation, debugging and characterization of common high-speed serial bus designs including I2C, CAN/LIN, SPI, Serial ATA, Ethernet (Gb E), USB 2.0, Fire Wire (1394b); signal integrity, jitter and timing analysis; manufacturing engineering and test. Accurate measurements for serial and digital applications Excellent common mode rejection - reduces measurement ...