Teledyne LeCroy Oscilloscope Probe, Probe Type: Differential 120MHz 1.5kV 1:50, 1:500

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): US
Product Details

Teledyne LeCroy HVD3000A Series Probes

Teledyne LeCroy’s HVD3106A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 1.5 kV electrical apparatus. The 1% gain accuracy coupled with exceptional common-mode rejection ratio provides an accurate and versatile probe suitable for use with a wide range of oscilloscopes

Features and Benefits

  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range

  • 1% gain accuracy

  • High offset capability at both high and low attenuation

  • AC and DC coupling

  • ProBus active probe interface with automatic scaling

  • AutoZero with auto disconnect switch

  • Wide oscilloscope compatibility

Applications

  • Applications

  • Automotive

  • Power Applications

  • Motor Drive Development

  • Product Design Applications

  • 174-8868 - 1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
  • 174-8869 1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect

  • 174-8870 - 1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect

Supplied with

174-8869 and 174-8870 are supplied with = a Pair of Red & Black 1000V Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips and Spade Terminals

Specifications
Attribute Value
Probe Type Differential
Attenuation 1:50, 1:500
Bandwidth 120MHz
Maximum Common Mode Input Voltage 1.5kV
Number of Probes 1
Safety Category Level CAT III
Series HVD3000A
Safety Category CAT III 1000 Vrms
Rise Time 2.9ns
2 In stock for delivery within 1 working days
Price Each
£ 1,560.00
(exc. VAT)
£ 1,872.00
(inc. VAT)
Units
Per unit
1 +
£1,560.00
Not available for guaranteed pre 9am/10am delivery
Related Products
Bandwidth DC-70 MHz Rise time ≤5 ns DC ...
Description:
Bandwidth DC-70 MHz Rise time ≤5 ns DC accuracy ±2%Attenuation ratio 50 X/500 XMaximum differential test voltage (DC + Peak AC) 50 X: 150 V, 500 X: 1500 VMaximum input common mode voltage (voltage-to-earth Vrms) 600 V CATIII, 1000 V CATIIInput impedance single-ended to ground 5 MΩ, two inputs 10 ...
When you use the oscilloscope in its usual ...
Description:
When you use the oscilloscope in its usual context to show and measure circuit shaft formations, you are working in the most common mode for voltage measurements. The differential probe enhances the oscilloscope probe's measuring capabilities with performance conversion, inverters, motor speed indicators, switch mode power supplies and many other ...
For high-speed switch mode power supply design; CAN/LIN ...
Description:
For high-speed switch mode power supply design; CAN/LIN bus design; high-speed digital design; digital design and characterization; manufacturing engineering test; research and development. ±42 V (DC + pk AC) differential input voltage 18 dB CMRR (at 250 MHz 50X attenuation) Selectable bandwidth limiting filters DC reject Connects to some Tektronix ...
These high-voltage differential probes are for making, safely ...
Description:
These high-voltage differential probes are for making, safely and accurately, floating measurements in power electronics circuits. They enable conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements (i.e. where neither point of measurement is at earth ground). Selectable attenuation settings make for highly versatile probes which come with ...