RS PRO RS-218 Handheld Digital Multimeter, True RMS, 200mA ac Max, 200mA dc Max, 600V ac Max - RS Calibrated
- RS Stock No.:
- 192-5978
- Brand:
- RS PRO
Subtotal (1 unit)*
£90.21
(exc. VAT)
£108.25
(inc. VAT)
FREE delivery for orders over £50.00
- 181 unit(s) ready to ship
Units | Per unit |
---|---|
1 + | £90.21 |
*price indicative
- RS Stock No.:
- 192-5978
- Brand:
- RS PRO
Select all | Attribute | Value |
---|---|---|
Brand | RS PRO | |
Multimeter Type | Handheld | |
Display Type | Digital | |
Model Number p | RS-218 | |
Calibrated | RSCAL | |
Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | |
Absolute Maximum DC Voltage Measurement | 600V dc | |
Absolute Maximum AC Voltage Measurement | 600V ac | |
Absolute Maximum AC Current Measurement | 200mA ac | |
Absolute Maximum Resistance Measurement | 40MΩ | |
Absolute Maximum DC Current Measurement | 200mA dc | |
Absolute Maximum Capacitance Measurement | 100µF | |
True RMS | Yes | |
Maximum Frequency | 10kHz | |
DC Current Measurement Resolution | 0.1µA dc | |
AC Current Measurement Resolution | 0.1µA ac | |
Resistance Measurement Resolution | 100mΩ | |
DC Voltage Measurement Resolution | 0.1mV dc | |
AC Voltage Measurement Resolution | 1mV ac | |
Capacitance Measurement Resolution | 10pF | |
Safety Category Level | CAT IV | |
Best AC Current Accuracy | ±2.5 % | |
Best AC Voltage Accuracy | ±1 % | |
Best Capacitance Measurement Accuracy | ±3 % | |
Minimum Operating Temperature | 0°C | |
Height | 116mm | |
Maximum Operating Temperature | +40°C | |
Safety Category Voltage | 600V | |
Best Resistance Measurement Accuracy | ±0.8 % | |
Weight | 145g | |
Battery Type | AAA | |
Best DC Current Accuracy | ±2 % | |
Dimensions | 59 x 36 x 116mm | |
Best DC Voltage Accuracy | ±0.5 % | |
Length | 59mm | |
Width | 36mm | |
Select all | ||
---|---|---|
Brand RS PRO | ||
Multimeter Type Handheld | ||
Display Type Digital | ||
Model Number p RS-218 | ||
Calibrated RSCAL | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | ||
Absolute Maximum DC Voltage Measurement 600V dc | ||
Absolute Maximum AC Voltage Measurement 600V ac | ||
Absolute Maximum AC Current Measurement 200mA ac | ||
Absolute Maximum Resistance Measurement 40MΩ | ||
Absolute Maximum DC Current Measurement 200mA dc | ||
Absolute Maximum Capacitance Measurement 100µF | ||
True RMS Yes | ||
Maximum Frequency 10kHz | ||
DC Current Measurement Resolution 0.1µA dc | ||
AC Current Measurement Resolution 0.1µA ac | ||
Resistance Measurement Resolution 100mΩ | ||
DC Voltage Measurement Resolution 0.1mV dc | ||
AC Voltage Measurement Resolution 1mV ac | ||
Capacitance Measurement Resolution 10pF | ||
Safety Category Level CAT IV | ||
Best AC Current Accuracy ±2.5 % | ||
Best AC Voltage Accuracy ±1 % | ||
Best Capacitance Measurement Accuracy ±3 % | ||
Minimum Operating Temperature 0°C | ||
Height 116mm | ||
Maximum Operating Temperature +40°C | ||
Safety Category Voltage 600V | ||
Best Resistance Measurement Accuracy ±0.8 % | ||
Weight 145g | ||
Battery Type AAA | ||
Best DC Current Accuracy ±2 % | ||
Dimensions 59 x 36 x 116mm | ||
Best DC Voltage Accuracy ±0.5 % | ||
Length 59mm | ||
Width 36mm | ||
- COO (Country of Origin):
- CN
RS PRO Pocket Handheld Multimeter with NCV Tester
Features and benefits
• MODE button
• Rotary function
• Hz/% Duty Cycle switch
• Large high contrast 4000 counts LCD display with backlight feature
• Safety category CAT IV, 600V
• Variety of functions including frequency, resistance, capacitance, diode test, continuity
• A range of functions measured including AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance
• Compact design, ideal for working on the go
• Auto power off to preserve battery life
• Flashlight feature, ideal for working in dark environments
• 200mA fused protection
• Test leads included
• Double molded enclosure offering excellent protection
Applications
Compact design
Non-Contact Voltage Detector and Indicator
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation.
1. The non-contact voltage detector operates when the meter is set to any measuring function. The detector does not operate when Auto Power Off turns the meter off or when the rotary function switch is set to the off position.
2. Hold the detector close to the AC voltage being tested.
3. If AC voltage within the specified range is present, the indicator light will illuminate.
NOTE: Insulation type and thickness, and distance from the voltage source and other factors may effect operation. Use other methods to verify live voltage if there is any uncertainty.
NOTE: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation.
NOTE: The detector only activates the indicator light when AC voltage is present. It does not indicate the voltage level on the LCD display.