Siemens 3 Phase Soft Starter - 9 A Current Rating, 4 kW Power Rating, 230 → 400 V Supply Voltage
- RS Stock No.:
- 351-5123
- Mfr. Part No.:
- 3RW30161CB14
- Brand:
- Siemens
Image representative of range
Unavailable
RS will no longer stock this product.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£171.98
(exc. VAT)
£206.38
(inc. VAT)
- RS Stock No.:
- 351-5123
- Mfr. Part No.:
- 3RW30161CB14
- Brand:
- Siemens
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Power Rating | 4 kW | |
| Voltage Rating | 400 V | |
| Phase | 3 | |
| Current Rating | 9 A | |
| IP Rating | IP20 | |
| Overall Length | 98mm | |
| Overall Width | 45mm | |
| Overall Depth | 98mm | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Power Rating 4 kW | ||
Voltage Rating 400 V | ||
Phase 3 | ||
Current Rating 9 A | ||
IP Rating IP20 | ||
Overall Length 98mm | ||
Overall Width 45mm | ||
Overall Depth 98mm | ||
RoHS Status: Not Applicable
Sirius 3RW30
May be integrated into a motor control system using other Sirius control gear products, e.g. 3 pole circuit breakers from the 3RV10 range (see Control Gear section)
Two phase control
Adjustable start-up voltage between 40 to 100% of working voltage
Integrated bypass contacts
DIN rail mounting
Compact design and dimensions
Status indication
Integrated 'self-hold' and 'end of start-up' auxiliary contacts. The self-hold contact is used for interlocking when controlled by a means of a simple 'on-off' pushbutton set up. The 'end of start up' signal may be used to operate other pieces of plant, such as a pump
Ideal replacement for DOL and Star-Delta starters
Two phase control
Adjustable start-up voltage between 40 to 100% of working voltage
Integrated bypass contacts
DIN rail mounting
Compact design and dimensions
Status indication
Integrated 'self-hold' and 'end of start-up' auxiliary contacts. The self-hold contact is used for interlocking when controlled by a means of a simple 'on-off' pushbutton set up. The 'end of start up' signal may be used to operate other pieces of plant, such as a pump
Ideal replacement for DOL and Star-Delta starters
Note
End of stand-up auxiliary contacts not available on 3 and 4kW units.
Related links
- Schneider Electric 3 Phase Soft Starter - 44 A Current Rating 400 V Supply Voltage
- ABB 3 Phase Soft Starter - 12 A Current Rating 5.5 kW Power Rating, 208 → 600 V Supply Voltage
- Carlo Gavazzi RSE Series Soft Starter 5.5 kW 3 Phase, IP20
- Siemens SIRIUS 3RW Soft Starter 160 kW 3 Phase
- Siemens SIRIUS 3RW Soft Starter 90 kW 3 Phase
- Jumo TYA-202 Surface Mount Power Controller Current, 400 V Supply Voltage
- Jumo MINI MCR-2-T-2RO-PT DIN Rail Power Controller Relay, 400 V Supply Voltage
- Siemens SIRIUS Soft Starter 22 kW 3 Phase, IP20