Carlo Gavazzi Voltage Monitoring Relay, 3 Phase, SPDT, DIN Rail
- RS Stock No.:
- 209-8591
- Mfr. Part No.:
- DPB02CM44
- Brand:
- Carlo Gavazzi
Subtotal (1 unit)*
£191.90
(exc. VAT)
£230.28
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 17 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £191.90 |
*price indicative
- RS Stock No.:
- 209-8591
- Mfr. Part No.:
- DPB02CM44
- Brand:
- Carlo Gavazzi
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Carlo Gavazzi | |
Monitoring Application | Voltage | |
Electrical Phase | 3 | |
Contact Configuration | SPDT | |
Voltage Sensitivity | Overvoltage, Undervoltage | |
Mounting Type | DIN Rail | |
Phase Sensitivity | Phase Loss, Phase Sequence | |
Frequency Sensing Range | 50 → 400Hz | |
Series | DPB02 | |
Length | 99.5mm | |
Dimensions | 99.5 x 22.5 x 80mm | |
Operating Temperature Range | +60°C | |
Width | 22.5mm | |
Height | 80mm | |
Minimum Operating Temperature | -20°C | |
Maximum Operating Temperature | +60°C | |
Terminal Type | Screw | |
Select all | ||
---|---|---|
Brand Carlo Gavazzi | ||
Monitoring Application Voltage | ||
Electrical Phase 3 | ||
Contact Configuration SPDT | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity Phase Loss, Phase Sequence | ||
Frequency Sensing Range 50 → 400Hz | ||
Series DPB02 | ||
Length 99.5mm | ||
Dimensions 99.5 x 22.5 x 80mm | ||
Operating Temperature Range +60°C | ||
Width 22.5mm | ||
Height 80mm | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +60°C | ||
Terminal Type Screw | ||
- COO (Country of Origin):
- IT
The Carlo Gavazzi voltage monitoring relay can operate on both 3Ph and 3Ph+N mains detecting, besides the phase loss and the correct phase sequence, possible overvoltages and undervoltages. The power supply is provided by the monitored mains is wide input range and switch mode. A delay on alarm, up to 30s, for the over/under voltage alarms, filters unwanted trippings for temporary conditions.
Wide input voltage range and frequency
Asymmetry trip level can be adjusted from 2% to 22%
Switch mode power supply
Output LED indication
22.5mm standard DIN enclosure
Relay contact output for indication of the alarms/output status
Asymmetry trip level can be adjusted from 2% to 22%
Switch mode power supply
Output LED indication
22.5mm standard DIN enclosure
Relay contact output for indication of the alarms/output status