Siemens, SENTRON MCCB 3P 250A, Breaking Capacity 25 kA, 36 kA, Fixed Mount
- RS Stock No.:
- 874-4137
- Distrelec Article No.:
- 301-37-944
- Mfr. Part No.:
- 3VA1110-4ED36-0AA0
- Brand:
- Siemens
Subtotal (1 unit)*
£221.42
(exc. VAT)
£265.70
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 27 October 2025
Units | Per unit |
---|---|
1 + | £221.42 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 874-4137
- Distrelec Article No.:
- 301-37-944
- Mfr. Part No.:
- 3VA1110-4ED36-0AA0
- Brand:
- Siemens
Select all | Attribute | Value |
---|---|---|
Brand | Siemens | |
Range | SENTRON | |
Series | 3VA | |
Number of Poles | 3 | |
Current Rating | 250A | |
Breaking Capacity at Maximum Voltage Rating | 25 kA, 36 kA | |
Rated AC Voltage | 690V | |
Rated DC Voltage | 500V | |
Mounting Style | Fixed | |
Length | 76.2mm | |
Width | 130mm | |
Depth | 88mm | |
Better World Product | Yes | |
Better World Claim | Extended product life, Saves energy | |
Break Time | Instantaneous | |
Reset Actuator Type | Toggle Switch | |
Circuit Breaker Type | MCCB | |
Tripping Mechanism | Thermal-Magnetic | |
Mounting Hole Diameter | 4.2mm | |
Select all | ||
---|---|---|
Brand Siemens | ||
Range SENTRON | ||
Series 3VA | ||
Number of Poles 3 | ||
Current Rating 250A | ||
Breaking Capacity at Maximum Voltage Rating 25 kA, 36 kA | ||
Rated AC Voltage 690V | ||
Rated DC Voltage 500V | ||
Mounting Style Fixed | ||
Length 76.2mm | ||
Width 130mm | ||
Depth 88mm | ||
Better World Product Yes | ||
Better World Claim Extended product life, Saves energy | ||
Break Time Instantaneous | ||
Reset Actuator Type Toggle Switch | ||
Circuit Breaker Type MCCB | ||
Tripping Mechanism Thermal-Magnetic | ||
Mounting Hole Diameter 4.2mm | ||
- COO (Country of Origin):
- CZ
Siemens 3VA1 MCCBs
The devices of the 3VA1 series fulfill all standard tasks in line protection, thanks to their particularly compact design, 3VA1 MCCBs are the perfect choice for applications in distribution boards and machine engineering.
They are easily mounted as fixed or plug-in versions.
The basic trigger for overload or short-circuit protection is a thermal-magnetic, electronic trip unit (TMTU) and is suitable for use in three-phase, AC, and DC networks.
Thermal-magnetic trip units
AC/DC applications
No derating up to +50 °C
Related links
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens Breaking Capacity 36 kA, Fixed Mount