ABB System M Pro S200 MCB, 3P, 10A Curve B, 400V AC, 125V DC, 10 kA Breaking Capacity
- RS Stock No.:
- 288-0883
- Mfr. Part No.:
- 2CDS253001R0105
- Brand:
- ABB
Subtotal (1 unit)*
£62.87
(exc. VAT)
£75.44
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 4 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £62.87 |
*price indicative
- RS Stock No.:
- 288-0883
- Mfr. Part No.:
- 2CDS253001R0105
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Number of Poles | 3 | |
| Current Rating | 10A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 400V | |
| Rated DC Voltage | 125V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | System M Pro | |
| Series | S200 | |
| Circuit Breaker Type | MCB | |
| Length | 88mm | |
| Width | 52.5mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 69mm | |
| Reset Actuator Type | Lever | |
| Application | Commercial, Industrial | |
| Special Features | Short Circuit Protection | |
| Terminal Contact Type | Screw | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Number of Poles 3 | ||
Current Rating 10A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 400V | ||
Rated DC Voltage 125V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range System M Pro | ||
Series S200 | ||
Circuit Breaker Type MCB | ||
Length 88mm | ||
Width 52.5mm | ||
Mounting Style DIN Rail Mount | ||
Depth 69mm | ||
Reset Actuator Type Lever | ||
Application Commercial, Industrial | ||
Special Features Short Circuit Protection | ||
Terminal Contact Type Screw | ||
RoHS Status: Exempt
- COO (Country of Origin):
- DE
ABB S200 Series MCB, 10A Current Rating, 10kA Breaking Capacity (at Maximum Voltage Rating) - 2CDS253001R0105
This circuit breaker is designed to protect electrical circuits in commercial and industrial environments. It provides safety against electrical overload and short circuits, making it a vital component in various electrical systems. With a high breaking capacity of 10 kA, it effectively handles fault conditions, ensuring user safety.
Features & Benefits
• Provides short circuit protection to enhance system safety
• Incorporates a thermal electromechanical mechanism for consistent operation
• Rated for 400V AC, accommodating a variety of power Applications
• Screw terminal contact type ensures secure electrical connections
• Compact width of 52.5mm allows for efficient space utilisation on DIN rail
• Type B characteristic suitable for general Applications
• Incorporates a thermal electromechanical mechanism for consistent operation
• Rated for 400V AC, accommodating a variety of power Applications
• Screw terminal contact type ensures secure electrical connections
• Compact width of 52.5mm allows for efficient space utilisation on DIN rail
• Type B characteristic suitable for general Applications
Applications
• Utilised in commercial electrical installations for circuit protection
• Suitable for industrial machinery requiring effective current management
• Ideal for controlling electric motors and resistive loads
• Compatible with systems that need robust overload protection
• Employed in automation setups demanding precise circuit safeguarding
• Suitable for industrial machinery requiring effective current management
• Ideal for controlling electric motors and resistive loads
• Compatible with systems that need robust overload protection
• Employed in automation setups demanding precise circuit safeguarding
What is the current rating suitable for?
The 10 A current rating is appropriate for various light to medium load applications.
How does it handle short circuit conditions?
It automatically disconnects the circuit upon detecting a short circuit, preventing equipment damage.
Can this be easily installed on a DIN rail?
Yes, it is designed for straightforward installation on standard DIN rails.
What maintenance is required for optimal performance?
Regular inspections are recommended to ensure proper functionality, as dust or debris can affect performance.
Is it compatible with other circuit protection devices?
Yes, it can be integrated with additional protective devices in a comprehensive electrical system.
Related links
- ABB System Pro M Compact S200 MCB 10A Curve B 10 kA Breaking Capacity
- ABB System M Pro S200 MCB 20A Curve B 12V DC, 10 kA Breaking Capacity
- ABB System M Pro S200 MCB 16A Curve B 12V DC, 10 kA Breaking Capacity
- Eaton xPole PXL 3P 400V AC 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 10A Curve D 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 50A Curve B 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 2A Curve B 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 32A Curve B 125V DC, 10 kA Breaking Capacity