Schneider Electric A9F A9F Miniature Circuit Breaker, 1-Pole, 32A, Type B, 500V ac AC, 60 V dc DC
- RS Stock No.:
- 335-058
- Mfr. Part No.:
- A9F93132
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£53.66
(exc. VAT)
£64.39
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | £53.66 |
*price indicative
- RS Stock No.:
- 335-058
- Mfr. Part No.:
- A9F93132
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Number of Poles | 1 | |
| Product Type | Miniature Circuit Breaker | |
| Current Rating | 32A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 500V ac | |
| Rated DC Voltage | 60V dc | |
| Range | A9F | |
| Series | A9F | |
| Terminal Type | Single Terminal | |
| IP Rating | IP20 | |
| Height | 85mm | |
| Width | 18mm | |
| Standards/Approvals | EN 60947-2 EN 60898-1 IEC 60947-2 IEC 60898-1, RoHS | |
| Depth | 78.5mm | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Number of Poles 1 | ||
Product Type Miniature Circuit Breaker | ||
Current Rating 32A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 500V ac | ||
Rated DC Voltage 60V dc | ||
Range A9F | ||
Series A9F | ||
Terminal Type Single Terminal | ||
IP Rating IP20 | ||
Height 85mm | ||
Width 18mm | ||
Standards/Approvals EN 60947-2 EN 60898-1 IEC 60947-2 IEC 60898-1, RoHS | ||
Depth 78.5mm | ||
- COO (Country of Origin):
- FR
The Schneider Electric Acti9 iC60L is a low voltage miniature circuit breaker. It has 1P with 1 protected pole, rated current 32A and B tripping curve. This miniature circuit breaker is for protection against short circuit and overload current in all applications. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
Suitability for industrial isolation according to IEC/EN 60947-2 standard
Combine short circuit and overload currents protection
Visitrip system for fast detection of faulty outgoers for shorter repair times
VisiSafe system for offering enhanced security when it comes to circuit protection
Related links
- Schneider Electric Acti9 iC60, 72 V dc DC
- Schneider Electric Acti9 iC60, 125 V dc DC
- Schneider Electric Acti9 iC60, 250 V dc DC
- Schneider Electric Acti9 iC60 70 kA Breaking Capacity
- Schneider Electric Acti9 iC60 70 kA Breaking Capacity
- Schneider Electric Acti9 iC60 Miniature Circuit Breaker 1.6 A 500 V ac AC 15000 A
- Schneider Electric Acti9 Acti9 iC60 Miniature Circuit Breaker 20 A 180 V dc DC, 15000 A Breaking
- Schneider Electric Acti9 Acti9 iC60 Miniature Circuit Breaker 3 A 440 V ac AC 70 kA