Schneider Electric Twido Series Logic Module, 24 V dc Supply, Relay Output, 9-Input, Sink, Source Input
- RS Stock No.:
- 528-8615
- Mfr. Part No.:
- TWDLCDA16DRF
- Brand:
- Schneider Electric
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£226.40
(exc. VAT)
£271.68
(inc. VAT)
- RS Stock No.:
- 528-8615
- Mfr. Part No.:
- TWDLCDA16DRF
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Manufacturer Series | Twido | |
| Number of Inputs | 9 | |
| Output Type | Relay | |
| Supply Voltage | 24 V dc | |
| Input Type | Sink, Source | |
| Number of Outputs | 7 | |
| Maximum Operating Temperature | +50°C | |
| Width | 80mm | |
| Length | 90mm | |
| Depth | 70mm | |
| Program Capacity | 2000 Instructions | |
| Display Included | Yes | |
| Communication Port Type | RS485 | |
| Dimensions | 90 x 80 x 70 mm | |
| Number of Communication Ports | 1 | |
| Output Current | 2 A | |
| Minimum Operating Temperature | 0°C | |
| Programming Interface | Computer, HMI | |
| Programming Language Used | Ladder Logic | |
| Mounting Type | DIN Rail | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Manufacturer Series Twido | ||
Number of Inputs 9 | ||
Output Type Relay | ||
Supply Voltage 24 V dc | ||
Input Type Sink, Source | ||
Number of Outputs 7 | ||
Maximum Operating Temperature +50°C | ||
Width 80mm | ||
Length 90mm | ||
Depth 70mm | ||
Program Capacity 2000 Instructions | ||
Display Included Yes | ||
Communication Port Type RS485 | ||
Dimensions 90 x 80 x 70 mm | ||
Number of Communication Ports 1 | ||
Output Current 2 A | ||
Minimum Operating Temperature 0°C | ||
Programming Interface Computer, HMI | ||
Programming Language Used Ladder Logic | ||
Mounting Type DIN Rail | ||
RoHS Status: Exempt
- COO (Country of Origin):
- TW
Twido Compact Controller
24 Vdc inputs
Isolated outputs
100base-TX ethernet via RJ45
Output rating for relay outputs: 2A@ 250Vac
Output rating for transistor outputs: 0.3A@ 24Vdc
Dimensions: H90 x W80 x D70mm (10 and 16 I/O)
H90 x W95 x D70mm (24 I/O)
H90 x W157 x D70mm (40 I/O)
Isolated outputs
100base-TX ethernet via RJ45
Output rating for relay outputs: 2A@ 250Vac
Output rating for transistor outputs: 0.3A@ 24Vdc
Dimensions: H90 x W80 x D70mm (10 and 16 I/O)
H90 x W95 x D70mm (24 I/O)
H90 x W157 x D70mm (40 I/O)
Schneider Electric Twido Base Units - Additional Info:
Twido programmable controller from Telemecanique providing flexible automation solutions for the control systems. Designed to be user-friendly and flexible, with powerful control functions.
Small footprint reduces panel size for applications where space is limited
Flexible cabling choices (removable screw terminal blocks and spring-type connectors for expandable units), allowing quick and easy wiring
Suitable for applications requiring 10 - 264 I/O points
Compact controllers available with 10, 16, 24 or 40 I/O points
Each controller has an RS-485 programming port and stock no. 528-8643 also has an RJ45 ethernet port
Modular controllers available with 20 or 40 I/O points
All products in the Twido range meet the standards of the following regulatory agencies: IEC61131-2, UL1604/CSA C22.2 No.213 (class 1, division 2, groups A, B, C, D), CE and TÜV
Flexible cabling choices (removable screw terminal blocks and spring-type connectors for expandable units), allowing quick and easy wiring
Suitable for applications requiring 10 - 264 I/O points
Compact controllers available with 10, 16, 24 or 40 I/O points
Each controller has an RS-485 programming port and stock no. 528-8643 also has an RJ45 ethernet port
Modular controllers available with 20 or 40 I/O points
All products in the Twido range meet the standards of the following regulatory agencies: IEC61131-2, UL1604/CSA C22.2 No.213 (class 1, division 2, groups A, B, C, D), CE and TÜV
Maximum I/O configuration
In order to connect all digital Input/Output modules and analogue Input/Output modules to base controllers, units should be built on DIN rails starting from the right-hand side of the bases, according to the following rules:
10 and 16 I/O compact bases cannot be expanded
24 I/O compact bases, can accommodate up to a maximum of 4 modules
40 I/O compact bases, can accommodate up to a maximum of 7 modules
20 I/O modular bases, can accommodate up to a maximum of 4 modules
40 I/O modular bases, can accommodate up to a maximum of 7 modules
24 I/O compact bases, can accommodate up to a maximum of 4 modules
40 I/O compact bases, can accommodate up to a maximum of 7 modules
20 I/O modular bases, can accommodate up to a maximum of 4 modules
40 I/O modular bases, can accommodate up to a maximum of 7 modules