Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Actuator Type | Roller Plunger | |
| Product Type | Limit Switch | |
| IP Rating | IP68, IP66, IP67 | |
| Contact Configuration | 1 NO/1 NC | |
| Housing Material | Zinc Alloy | |
| Contact Type | Snap Action | |
| Terminal Type | Cable | |
| Switching Current | 1.5 A | |
| Series | XCMD | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 240 V ac | |
| Switching DC Voltage | 250 V dc | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | CCC, CSA, REACH, RoHS, UL | |
| Depth | 16mm | |
| Width | 30 mm | |
| Length | 50mm | |
| Hazardous Area Certification | No | |
| Operating Force | 7N | |
| Mechanical Life | 10000000Cycles | |
| Select all | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Actuator Type Roller Plunger | ||
Product Type Limit Switch | ||
IP Rating IP68, IP66, IP67 | ||
Contact Configuration 1 NO/1 NC | ||
Housing Material Zinc Alloy | ||
Contact Type Snap Action | ||
Terminal Type Cable | ||
Switching Current 1.5 A | ||
Series XCMD | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 240 V ac | ||
Switching DC Voltage 250 V dc | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals CCC, CSA, REACH, RoHS, UL | ||
Depth 16mm | ||
Width 30 mm | ||
Length 50mm | ||
Hazardous Area Certification No | ||
Operating Force 7N | ||
Mechanical Life 10000000Cycles | ||
RoHS Status: Exempt
- COO (Country of Origin):
- ID
Telemecanique Sensors Limit Switch, 1.5A Maximum Current, NO/NC Configuration - OsiSense XC Series - XCMD2102L1
Take the hard work out of controlling your equipment with this limit switch from Telemecanique Sensors. It's an essential part of an automated setup as it makes or breaks an electrical connection to stop or start machinery. The switch is triggered when the spring-return roller plunger actuator makes contact with a moving part. Snap-action contacts ensure a high level of switching accuracy. As the unit's body is made from durable metal, it's a hardwearing option that stands up bumps and abrasions.
Features & Benefits
• Housing made from zinc alloy, which is resistant to corrosion in humid areas
• Operates reliably in challenging temperatures between -25°C and +70°C
• Compact dimensions of 50 (L) x 30 (W) x 16mm (D) so it's space-saving
• IP68 rating means it's shielded from dust and withstands submersion in 1.5m of water for 30 minutes
• Shock resistance of 25gn for 18ms makes it suitable for heavy industrial environments
Applications
• Production lines
• Escalators
• Mechanical engineering
Is this limit switch protected against short circuits?
Yes, it has a 6A cartridge fuse, so your equipment is protected if a short circuit occurs.
Telemecanique Limit Switches
Introducing Telemecanique miniature range of limit switches and accessories. These Telemecanique limit switches are the perfect solution for a multitude of applications including escalators, electrical assembly equipment and material handling. A limit switch is commonly made up of an actuator head, switch body and receptacle and predominantly used as part of a control system within industrial applications such as those listed before. Comprised of reinforced UL-VO thermoplastic which offers double insulation and protection of IP66.
How does a limit switch work?
The limit switches function through a contact proximity sensor device that features an actuator that is mechanically linked to a set of output contacts. When an object comes into contact with the actuator, the device then operates the contacts to make or break the electrical connection.
Related links
- Telemecanique Sensors XCMD Series Roller Plunger Limit Switch IP66 IP68 Zinc Alloy Housing, 240V ac
- Telemecanique Sensors XCMD Series Roller Plunger Limit Switch IP67 DP 240V ac Max,
- Telemecanique Sensors XCMD Series Plunger Limit Switch IP66 IP68 Zinc Alloy Housing
- Telemecanique Sensors XCMD Series Roller Lever Limit Switch IP66 IP68 Zinc Alloy Housing, 240V ac
- Telemecanique Sensors XCMD Series Roller Lever Plunger Limit Switch IP66 IP68 Zinc Alloy Housing,
- Telemecanique Sensors XCMD Series Plunger Limit Switch IP66 IP68 Zinc Alloy Housing, 240V ac
- Telemecanique Sensors XCMD Series Plunger Limit Switch IP66 IP68 Zinc Alloy Housing
- Telemecanique Sensors XCMD Series Roller Lever Limit Switch IP66 IP68 Zinc Alloy Housing, 240V ac