Endress+Hauser Nivotester FTL325N Series Vibronic Point Level Detection Level Sensor, DIN Rail, Polycarbonate,
- RS Stock No.:
- 287-1762
- Mfr. Part No.:
- FTL325N-H3E3
- Brand:
- Endress+Hauser
Subtotal (1 unit)*
£236.37
(exc. VAT)
£283.64
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 24 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £236.37 |
*price indicative
- RS Stock No.:
- 287-1762
- Mfr. Part No.:
- FTL325N-H3E3
- Brand:
- Endress+Hauser
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Endress+Hauser | |
Device Type | Vibronic Point Level Detection | |
Mounting Type | DIN Rail | |
Body Material | Polycarbonate, Polypropylene | |
Cable Length | 1000m | |
Series | Nivotester FTL325N | |
Hazardous Area Certification | ATEX | |
Select all | ||
---|---|---|
Brand Endress+Hauser | ||
Device Type Vibronic Point Level Detection | ||
Mounting Type DIN Rail | ||
Body Material Polycarbonate, Polypropylene | ||
Cable Length 1000m | ||
Series Nivotester FTL325N | ||
Hazardous Area Certification ATEX | ||
- COO (Country of Origin):
- DE
The ENDRESS+HAUSER switching unit for point level detection in liquid tanks, suitable for use in hazardous explosion areas. It is also ideal for overfill prevention in tanks with combustible or non-combustible liquids harmful to water. With its two-point control and point level detection capabilities, this product is perfect for applications in safety-related systems with requirements for functional safety up to SIL2 according to IEC 61508/IEC 61511. The switching unit features a NAMUR input for rail mounting or single installation and has an ambient temperature range of -20 to +50°C (-4 to +122°F). It also has international explosion protection certificates and overfill prevention WHG as well as marine approvals.
Switching unit for point level detection in liquid tanks
Suitable for use in hazardous explosion areas
Ideal for overfill prevention in tanks with harmful liquids
Two-point control and point level detection
Functional safety up to SIL2 according to IEC 61508/IEC 61511
NAMUR input for rail mounting or single installation
Ambient temperature range of -20 to +50°C (-4 to +122°F)
International explosion protection certificates
Overfill prevention WHG and marine approvals
Suitable for use in hazardous explosion areas
Ideal for overfill prevention in tanks with harmful liquids
Two-point control and point level detection
Functional safety up to SIL2 according to IEC 61508/IEC 61511
NAMUR input for rail mounting or single installation
Ambient temperature range of -20 to +50°C (-4 to +122°F)
International explosion protection certificates
Overfill prevention WHG and marine approvals
Related links
- Endress+Hauser Nivotester FTL325N Series Vibronic Point Level Detection Level Sensor Polycarbonate,
- Endress+Hauser Nivotester FTL325P Series Vibronic Point Level Detection Level Sensor Polycarbonate,
- Endress+Hauser Nivotester FTC325 Series Capacitance Point Level Switch Level Sensor Polycarbonate,
- Endress+Hauser Nivotester FTW325 Series Capacitance Level Sensors DIN Rail
- Endress+Hauser FTW325 Series Conductive Level Switch DIN Rail ATEX-Rated
- Endress+Hauser Nivotester Series Level Switch Level Sensors DIN Rail, PP Body
- Endress+Hauser Soliswitch FTE20 Series Point Level Level Sensors Threaded Mount
- CK Polyester, 4 Pocket Tool Belt Pouch