XP Power JHM20 DC-DC Converter, 12V dc/ 1.67A Output, 9 → 18 V dc Input, 20W, Through Hole, +80°C Max Temp -40°C
- RS Stock No.:
 - 177-4609
 - Mfr. Part No.:
 - JHM2012S12
 - Brand:
 - XP Power
 
Subtotal (1 unit)*
£56.54
(exc. VAT)
£67.85
(inc. VAT)
FREE delivery for orders over £50.00
- 999,999,999 left, ready to ship
 
Units  | Per unit  | 
|---|---|
| 1 - 4 | £56.54 | 
| 5 - 9 | £54.85 | 
| 10 - 24 | £53.15 | 
| 25 - 49 | £51.45 | 
| 50 + | £49.76 | 
*price indicative
- RS Stock No.:
 - 177-4609
 - Mfr. Part No.:
 - JHM2012S12
 - Brand:
 - XP Power
 
Select all  | Attribute | Value | 
|---|---|---|
| Brand | XP Power | |
| Output Voltage | 12V dc | |
| Input Voltage Range | 9 → 18 V dc | |
| Power Rating | 20W | |
| Input Voltage Nominal | 12 V dc | |
| Output Current | 1.67A | |
| Mounting Type | Through Hole | |
| Isolated | Yes | |
| Number of Outputs | 1 | |
| Output Voltage Adjustment Range | ±10% | |
| Package | 2 x 1 in | |
| Isolation Voltage | 4kV dc | |
| Depth | 10.2mm | |
| Width | 25.4mm | |
| Length | 50.8mm | |
| Series | JHM20 | |
| Load Regulation | ±2% | |
| Minimum Temperature | -40°C | |
| Medical Approved | Yes | |
| Maximum Temperature | +80°C | |
| Standards Met | ANSI/AAMI ES60601-1, CSA C22.2, EN55011, EN60068-2-27, EN60068-2-47, EN60068-2-6, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC60601-1, IEC60601-1-2, IEC60664-1, UL Listed | |
| Select all | ||
|---|---|---|
Brand XP Power  | ||
Output Voltage 12V dc  | ||
Input Voltage Range 9 → 18 V dc  | ||
Power Rating 20W  | ||
Input Voltage Nominal 12 V dc  | ||
Output Current 1.67A  | ||
Mounting Type Through Hole  | ||
Isolated Yes  | ||
Number of Outputs 1  | ||
Output Voltage Adjustment Range ±10%  | ||
Package 2 x 1 in  | ||
Isolation Voltage 4kV dc  | ||
Depth 10.2mm  | ||
Width 25.4mm  | ||
Length 50.8mm  | ||
Series JHM20  | ||
Load Regulation ±2%  | ||
Minimum Temperature -40°C  | ||
Medical Approved Yes  | ||
Maximum Temperature +80°C  | ||
Standards Met ANSI/AAMI ES60601-1, CSA C22.2, EN55011, EN60068-2-27, EN60068-2-47, EN60068-2-6, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC60601-1, IEC60601-1-2, IEC60664-1, UL Listed  | ||
- COO (Country of Origin):
 - CN
 
2 x MOPP at 250 VAC Working Voltage
2.5 μA Patient Leakage Current
Compact 1 x 2 Footprint
3 Year Warranty
Related links
- XP Power JHM20 DC-DC Converter 36 → 75 V dc Input Through Hole, +80°C Max Temp
 - XP Power JHM20 DC-DC Converter 18 → 36 V dc Input Through Hole, +80°C Max Temp -40°C
 - XP Power JHM20 DC-DC Converter 9 → 18 V dc Input Through Hole, +80°C Max Temp -40°C
 - XP Power JHM20 DC-DC Converter 9 → 18 V dc Input Through Hole, +80°C Max Temp -40°C Min
 - XP Power JHM20 DC-DC Converter 36 → 75 V dc Input Through Hole, +80°C Max Temp -40°C
 - XP Power JHM20 DC-DC Converter 36 → 75 V dc Input Through Hole, +80°C Max Temp -40°C
 - XP Power JHM20 DC-DC Converter 9 → 18 V dc Input Through Hole, +80°C Max Temp
 - XP Power JHM20 DC-DC Converter 18 → 36 V dc Input Through Hole, +80°C Max Temp
 