Recom REM10 DC-DC Converter, 12V dc/ 830mA Output, 5.5 → 9 V dc Input, 10W, Through Hole, +105°C Max Temp -40°C
- RS Stock No.:
- 166-6521
- Mfr. Part No.:
- REM10-0512S/A
- Brand:
- Recom
Subtotal (1 tube of 7 units)*
£502.27
(exc. VAT)
£602.72
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 24 December 2025
Tube(s) | Per Tube | Per unit* |
---|---|---|
1 - 4 | £502.27 | £71.753 |
5 - 9 | £487.19 | £69.599 |
10 - 24 | £472.13 | £67.447 |
25 - 49 | £457.05 | £65.293 |
50 + | £441.99 | £63.141 |
*price indicative
- RS Stock No.:
- 166-6521
- Mfr. Part No.:
- REM10-0512S/A
- Brand:
- Recom
Select all | Attribute | Value |
---|---|---|
Brand | Recom | |
Output Voltage | 12V dc | |
Input Voltage Range | 5.5 → 9 V dc | |
Power Rating | 10W | |
Input Voltage Nominal | 5 V dc | |
Output Current | 830mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 1 | |
Output Voltage Adjustment Range | ±10% | |
Package | DIP 24 | |
Isolation Voltage | 5kV ac | |
Depth | 10.4mm | |
Width | 20.3mm | |
Length | 31.8mm | |
Series | REM10 | |
Load Regulation | ±0.2% | |
Standards Met | ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A33, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A33, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | |
Maximum Temperature | +105°C | |
Efficiency | 86.5 %, 88 %, 89 % | |
Minimum Temperature | -40°C | |
Select all | ||
---|---|---|
Brand Recom | ||
Output Voltage 12V dc | ||
Input Voltage Range 5.5 → 9 V dc | ||
Power Rating 10W | ||
Input Voltage Nominal 5 V dc | ||
Output Current 830mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Output Voltage Adjustment Range ±10% | ||
Package DIP 24 | ||
Isolation Voltage 5kV ac | ||
Depth 10.4mm | ||
Width 20.3mm | ||
Length 31.8mm | ||
Series REM10 | ||
Load Regulation ±0.2% | ||
Standards Met ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A33, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A33, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | ||
Maximum Temperature +105°C | ||
Efficiency 86.5 %, 88 %, 89 % | ||
Minimum Temperature -40°C | ||
Related links
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM6 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C Min