Schneider Electric Variable Speed Drive, 37 kW, 3 Phase, 400 V ac, 68.9 A, ATV 212 Series
- RS Stock No.:
- 797-0710
- Mfr. Part No.:
- ATV212HD37N4
- Brand:
- Schneider Electric
Image representative of range
Subtotal (1 unit)*
£4,416.16
(exc. VAT)
£5,299.39
(inc. VAT)
FREE delivery for orders over £50.00
- 999,999,999 unit(s) shipping from 14 November 2025
Units | Per unit |
---|---|
1 + | £4,416.16 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 797-0710
- Mfr. Part No.:
- ATV212HD37N4
- Brand:
- Schneider Electric
Select all | Attribute | Value |
---|---|---|
Brand | Schneider Electric | |
Power Rating | 37 kW | |
Phase | 3 | |
Supply Voltage | 400 V ac | |
Current Rating | 68.9 A | |
Series | ATV 212 | |
For Use With | Asynchronous Motors | |
Field Bus Communication Type | Modbus | |
IP Rating | IP20, IP21, IP41 | |
Output Frequency | 0.5 → 200Hz | |
STO | No | |
Filter Included | Yes | |
Better World Verification | Green Premium | |
Better World Product | Yes | |
Overall Depth | 550mm | |
Overall Length | 240mm | |
Overall Width | 244mm | |
Select all | ||
---|---|---|
Brand Schneider Electric | ||
Power Rating 37 kW | ||
Phase 3 | ||
Supply Voltage 400 V ac | ||
Current Rating 68.9 A | ||
Series ATV 212 | ||
For Use With Asynchronous Motors | ||
Field Bus Communication Type Modbus | ||
IP Rating IP20, IP21, IP41 | ||
Output Frequency 0.5 → 200Hz | ||
STO No | ||
Filter Included Yes | ||
Better World Verification Green Premium | ||
Better World Product Yes | ||
Overall Depth 550mm | ||
Overall Length 240mm | ||
Overall Width 244mm | ||
- COO (Country of Origin):
- FR
Altivar ATV212 Variable Frequency Drive (VFD)
Features and Benefits
The communication service allows the user to monitor inhibitable, read device identification, read holding registers, configure a time out setting, and write multiple registers and write a single register.
Features an integrated class C2 EMC filter.
The Altivar is a frequency controller for a three phase, squirrel cage motor.
Available as standard IP21 and IP55 protection
Electrostatic discharge immunity test level 3, conforming to IEC 61000-4-2.
Less than 35% THDi harmonics due to Innovative C-less technology
Embedded Building management communication protocols.
Incorporates 3 logic inputs, 2 analogue inputs, 2 logic outputs and one configurable analogue output.
Typical Applications
Smoke extraction which has a forced start with fault inhibition.
Heating and Air conditioning, because of the optimised control in fluid processing and adjustable flow rates which improves energy management.
Pumping, useful in this application because of the multi-motor configuration and sleep/wake function. Alongside the detection of underload/over load.
When do the cooling fans on the ATV212 VFD switch on?
Schneider Electric ATV212HD37N4 Variable Speed Inverter Drive AVT212.
- Altivar 212 range.
- Variable speed drive.
- Short name – ATV212.
- Destination - Asynchronous motors.
- Specific application - Pumps and fans in HVAC.
- With a Heat Sink.
- 3 (three) Phase network.
- 37 kW motor power (50 Hp).
- Rated supply voltage 380 – 480 V.
- EMC Class C2 EMC filter integrated.
- 1 LED (red) for DC bus energized.
- Minimum switching current 3 MA at 24 V DC for configurable relay logic.
- Maximum switching current - 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R,) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R), 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R), 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R).
- Width – 240 mm, Height – 550 mm, Depth – 244 mm.
- Power dissipation 976 W.
- Specific application HVAC (HVAC Compressor, HVAC Fan, HVAC Pump).
- IP21 Protection.
- Vibration resistance - 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6, 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
- Shock resistance - 15 gn for 11 ms conforming to IEC 60068-2-27.
Protection Type.
- Overheating protection: drive.
- Thermal power stage: drive.
- Short-circuit between motor phases: drive.
- Input phase breaks: drive.
- Overcurrent between output phases and earth: drive.
- Over-voltages on the DC bus: drive.
- Break on the control circuit: drive.
- Against exceeding limit speed: drive.
- Line supply overvoltage and under-voltage: drive.
- Line supply under-voltage: drive.
- Against input phase loss: drive.
- Thermal protection: motor.
- Motor phase break: motor.
- With PTC probes: motor.
Standards.
- IEC 61800-3 environments 2 category C1, IEC 61800-3 environments 1 category C3, IEC 61800-3 category C3, IEC 61800-3 category C2, EN 61800-3, IEC 61800-3 environments 1 category C1, IEC 61800-5-1, EN 61800-3 environments 1 category, C1 EN 61800-3 category C3, IEC 61800-3 environments 2 category C2, EN 61800-3 category C2, EN 61800-3 environments 2 category C1, IEC 61800-3, EN 61800-3 environments 1 category C3, UL Type 1, IEC 61800-3 environments 2 category C3, IEC 61800-3 environments 1 category C2, EN 55011 class A group 1, EN 61800-5-1, EN 61800-3 environments 1 category C2, EN 61800-3 environments 2 category C3, EN 61800-3 environments 2 category C2.
Related links
- Schneider Electric Variable Speed Drive 3 Phase 54.4 A Altivar 212 Series
- Schneider Electric Variable Speed Drive 3 Phase 57.3 A, ATV950 Series
- Schneider Electric Variable Speed Drive 3 Phase 66.2 A, Altivar Series
- Schneider Electric Inverter Drive 3 Phase 68.9 A, ALTIVAR 212 Series
- Schneider Electric Inverter Drive 3 Phase 14.7 A, ATV 212 Series
- Schneider Electric Variable Speed Drive 37 kW 400 V ac 66.2 A, Altivar Series
- Schneider Electric Inverter Drive 3 Phase 21.1 A, ATV 212 Series
- Schneider Electric Inverter Drive 3 Phase 56.7 A, ATV 212 Series