MAX31855NASA+ Maxim Integrated, Thermocouple Amplifier, 3.3 V, 8-Pin SOIC
- RS Stock No.:
 - 146-1066
 - Mfr. Part No.:
 - MAX31855NASA+
 - Brand:
 - Maxim Integrated
 
Discontinued
- RS Stock No.:
 - 146-1066
 - Mfr. Part No.:
 - MAX31855NASA+
 - Brand:
 - Maxim Integrated
 
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all  | Attribute | Value | 
|---|---|---|
| Brand | Maxim Integrated | |
| Power Supply Type | Single | |
| Package Type | SOIC | |
| Mounting Type | Surface Mount | |
| Typical Single Supply Voltage | 3.3 V | |
| Pin Count | 8 | |
| Rail to Rail | No | |
| Minimum Operating Temperature | -200 °C | |
| Maximum Operating Temperature | +1300 °C | |
| Maximum Supply Current | 1500 μA | |
| Width | 4mm | |
| Length | 5mm | |
| Height | 1.5mm | |
| Dimensions | 5 x 4 x 1.5mm | |
| Select all | ||
|---|---|---|
Brand Maxim Integrated  | ||
Power Supply Type Single  | ||
Package Type SOIC  | ||
Mounting Type Surface Mount  | ||
Typical Single Supply Voltage 3.3 V  | ||
Pin Count 8  | ||
Rail to Rail No  | ||
Minimum Operating Temperature -200 °C  | ||
Maximum Operating Temperature +1300 °C  | ||
Maximum Supply Current 1500 μA  | ||
Width 4mm  | ||
Length 5mm  | ||
Height 1.5mm  | ||
Dimensions 5 x 4 x 1.5mm  | ||
Thermocouple Amplifiers, Maxim Integrated
Thermocouple-to-Digital Converter
Integrated Cold-Junction Compensation
Thermocouple Types: K-, J-, N-, T-, S-, R-, and E-Type
0.25°C Resolution
Detects Thermocouple Shorts to GND or VCC
Detects Open Thermocouple
Interfaces with simple SPI-Compatible Serial Interface (Read-Only) to Microcontrollers
Integrated Cold-Junction Compensation
Thermocouple Types: K-, J-, N-, T-, S-, R-, and E-Type
0.25°C Resolution
Detects Thermocouple Shorts to GND or VCC
Detects Open Thermocouple
Interfaces with simple SPI-Compatible Serial Interface (Read-Only) to Microcontrollers
Applications
	Industrial
 HVAC
 Appliances
 HVAC
 Appliances
Note
Please note that any defect or non – conformance of this product must be discovered and reported to RS within 20 days of purchase.
Thermocouple Amplifiers