Alpha Wire Ecogen Ecowire Series Red 0.2 mm² Hook Up Wire, 24 AWG, 7/0.20 mm, 30m, MPPE Insulation, 6712 RD005
- RS Stock No.:
- 687-7424
- Distrelec Article No.:
- 300-59-326
- Mfr. Part No.:
- 6712 RD005
- Brand:
- Alpha Wire
Subtotal (1 reel of 30 metres)*
£24.51
(exc. VAT)
£29.41
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- Plus 24 unit(s) shipping from 13 October 2025
- Plus 10 unit(s) shipping from 14 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
---|---|---|
1 + | £24.51 | £0.817 |
*price indicative
- RS Stock No.:
- 687-7424
- Distrelec Article No.:
- 300-59-326
- Mfr. Part No.:
- 6712 RD005
- Brand:
- Alpha Wire
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Alpha Wire | |
Cross Sectional Area | 0.2 mm² | |
Sheath Colour | Red | |
American Wire Gauge | 24 AWG | |
Cable Shape | Single Core | |
Core Strands | 7/0.20 mm | |
Length | 30m | |
Insulation Material | MPPE | |
Outer Diameter | 1.09mm | |
Voltage Rating | 600 V | |
Maximum Operating Temperature | +105°C | |
Minimum Operating Temperature | -40°C | |
Conductor Material | Copper | |
Wire Style | UL11028 | |
Standards Met | CE, CSA, UL | |
Series | Ecogen Ecowire | |
Shield Type | Unshielded | |
Insulation Wall Thickness | 0.3mm | |
Number of Strands | 7 | |
Size of Strands | 0.2 mm | |
Select all | ||
---|---|---|
Brand Alpha Wire | ||
Cross Sectional Area 0.2 mm² | ||
Sheath Colour Red | ||
American Wire Gauge 24 AWG | ||
Cable Shape Single Core | ||
Core Strands 7/0.20 mm | ||
Length 30m | ||
Insulation Material MPPE | ||
Outer Diameter 1.09mm | ||
Voltage Rating 600 V | ||
Maximum Operating Temperature +105°C | ||
Minimum Operating Temperature -40°C | ||
Conductor Material Copper | ||
Wire Style UL11028 | ||
Standards Met CE, CSA, UL | ||
Series Ecogen Ecowire | ||
Shield Type Unshielded | ||
Insulation Wall Thickness 0.3mm | ||
Number of Strands 7 | ||
Size of Strands 0.2 mm | ||
- COO (Country of Origin):
- MX
Belden Ecogen Ecowire Series Hook Up Wire, 0.2mm² Cross Sectional Area, Red - 6712 RD001
This hook up wire is a high-performance solution designed for reliable electrical connections in demanding environments. Made from tinned copper, this single core wire features a red MPPE insulation and operates effectively within a wide temperature range from -40 °C to +105 °C. Built to comply with stringent UK standards, the wire ensures optimal safety and performance.
Features & Benefits
• Compliant with 600V high temperature wire standards
• Tinned copper conductor enhances corrosion resistance
• Modified Polyphenylene Ether prevents thermal degradation
• Unshielded design allows for easy installation and flexibility
• Suitable for high-temperature applications up to +105 °C
• Lightweight construction facilitates hassle-free handling
• Tinned copper conductor enhances corrosion resistance
• Modified Polyphenylene Ether prevents thermal degradation
• Unshielded design allows for easy installation and flexibility
• Suitable for high-temperature applications up to +105 °C
• Lightweight construction facilitates hassle-free handling
Applications
• Utilised in automation systems for secure connections
• Employed in electronic devices requiring high temperature wire
• For wiring in mechanical assemblies where flexibility is needed
• Implemented in electrical systems for reliable hookup solutions
• Employed in electronic devices requiring high temperature wire
• For wiring in mechanical assemblies where flexibility is needed
• Implemented in electrical systems for reliable hookup solutions
What is the significance of using tinned copper for this wire?
Using tinned copper significantly reduces the risk of corrosion, enhancing the longevity and reliability of electrical connections in challenging environments.
How does the wire perform in applications with varying temperatures?
Designed to operate within a temperature range of -40 °C to +105 °C, it remains stable and functional in extreme conditions, making it versatile for various applications.
What advantages does the unshielded design provide?
The unshielded design offers greater flexibility and easier routing in tight spaces, making it ideal for intricate wiring within devices and machinery.
EcoWire ™
Related links
- Alpha Wire Ecogen Ecowire Series Yellow 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 YL005
- Alpha Wire Ecogen Ecowire Series Grey 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 SL005
- Alpha Wire Ecogen Ecowire Series Brown 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 BR005
- Alpha Wire Ecogen Ecowire Series Orange 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 OR005
- Alpha Wire Ecogen Ecowire Series Black 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 BK005
- Alpha Wire Ecogen Ecowire Series Green 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 GR005
- Alpha Wire Ecogen Ecowire Series Purple 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 VI005
- Alpha Wire Ecogen Ecowire Series White 0.2 mm² Hook Up Wire 7/0.20 mm MPPE Insulation, 6712 WH005