HARTING Heavy Duty Power Connector Insert, 16A, Han E Series Male, 10 Contacts
- RS Stock No.:
- 114-8232
- Distrelec Article No.:
- 143-42-705
- Mfr. Part No.:
- 09330102601
- Brand:
- HARTING
Bulk discount available
View bulk pricing optionsSubtotal (1 unit)*
£15.27
(exc. VAT)
£18.32
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 694 unit(s) ready to ship
- Plus 108 unit(s) ready to ship from another location
- Plus 876 unit(s) shipping from 21 October 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 9 | £15.27 |
| 10 - 24 | £14.67 |
| 25 - 49 | £14.05 |
| 50 + | £13.42 |
*price indicative
- RS Stock No.:
- 114-8232
- Distrelec Article No.:
- 143-42-705
- Mfr. Part No.:
- 09330102601
- Brand:
- HARTING
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | HARTING | |
| Current Rating | 16A | |
| Product Type | Heavy Duty Power Connector Insert | |
| Series | Han E | |
| Sub Type | Connector Insert | |
| Connector Gender | Male | |
| For Use With | Heavy Duty Power Connector | |
| Pole Format | 10+E | |
| Number of Rows | 2 | |
| Voltage | 500V | |
| Mount Type | Cable | |
| Number of Contacts | 10 | |
| Standards/Approvals | No | |
| Manufacturer Size Code | 10B | |
| Contact Material | Copper Alloy | |
| Minimum Wire Size mm² | 0.75mm² | |
| Maximum Wire Size mm² | 2.5mm² | |
| Thread Size | M3 x 10 | |
| Orientation | Straight | |
| Contact Plating | Silver | |
| Select all | ||
|---|---|---|
Brand HARTING | ||
Current Rating 16A | ||
Product Type Heavy Duty Power Connector Insert | ||
Series Han E | ||
Sub Type Connector Insert | ||
Connector Gender Male | ||
For Use With Heavy Duty Power Connector | ||
Pole Format 10+E | ||
Number of Rows 2 | ||
Voltage 500V | ||
Mount Type Cable | ||
Number of Contacts 10 | ||
Standards/Approvals No | ||
Manufacturer Size Code 10B | ||
Contact Material Copper Alloy | ||
Minimum Wire Size mm² 0.75mm² | ||
Maximum Wire Size mm² 2.5mm² | ||
Thread Size M3 x 10 | ||
Orientation Straight | ||
Contact Plating Silver | ||
- COO (Country of Origin):
- DE

Harting Han E Series Heavy Duty Power Connector Insert, 16A Current Rating, 500V Voltage - 09330102601
This heavy-duty power connector insert is a cable-mount male insert designed for industrial power distribution in automation and electrical systems. It provides a straight, 10+E pole arrangement for reliable mating in harsh-environment rectangular housings and is intended for use where compact, high-voltage, multi-contact power connections are required.
Features & Benefits
• Rated for 500V and 16 A for robust power handling
• Accepts 0.75–2.5 mm² conductors to suit varied cable gauges
• Silver-plated copper-alloy contacts for low electrical resistance
• Screw termination with wire protection for secure connections
• Mating durability of ≥500 cycles for frequent serviceability
• Accepts 0.75–2.5 mm² conductors to suit varied cable gauges
• Silver-plated copper-alloy contacts for low electrical resistance
• Screw termination with wire protection for secure connections
• Mating durability of ≥500 cycles for frequent serviceability
**Applications**
• Suitable for motor control and drive panel power connections
• Ideal for switchgear and distribution module wiring
• Used with heavy-duty cable-mount housings in factory automation
• Can be used for connectorised power feeds in machine tools
• Ideal for switchgear and distribution module wiring
• Used with heavy-duty cable-mount housings in factory automation
• Can be used for connectorised power feeds in machine tools
What conductor sizes does it accommodate?
It accepts conductors from 0.75 mm² up to 2.5 mm² and corresponds to AWG18–AWG14 for cross-reference.
Which termination and torque values should be used for installation?
Termination is by screw
contact screws and fixing screws use M3 with recommended torque 0.5 Nm and a slotted screwdriver 0.6 x 3.5mm or Phillips PH1/PH2.
How does the insert perform electrically under impulse conditions?
It is specified for rated impulse voltage up to 6 kV with insulation resistance exceeding 10^10 Ω and contact resistance ≤1 mΩ.
What thermal and mechanical endurance can installers expect?
Operational temperature range is −40 to +125 °C and the insert withstands at least 500 mating cycles.
Approvals
UL, CSA, SEV
Warning
These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of wrong connection.
Related links
- HARTING Heavy Duty Power Connector Insert Han E Series Male, 10 Contacts
- HARTING Heavy Duty Power Connector Insert Han E Series Female, 10 Contacts
- HARTING Heavy Duty Power Connector Insert Han E Greenline Series Male, 10 Contacts
- HARTING Heavy Duty Power Connector Insert Han E HMC Series Male, 10 Contacts
- HARTING Heavy Duty Power Connector Insert Han E HMC Series Female, 10 Contacts
- HARTING Insert Han E AV Series Male, 10 Contacts
- HARTING Heavy Duty Power Connector Insert Han E Series Male, 24 Contacts
- HARTING Heavy Duty Power Connector Insert Han E Series Female, 6 Contacts
