BK Precision 1826B Frequency Counter, 0.001 Hz Min, 6 GHz Max, 10 Digits Resolution

Subtotal (1 unit)*

£682.64

(exc. VAT)

£819.17

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 1 unit(s) shipping from 09 February 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£682.64

*price indicative

RS Stock No.:
296-903
Mfr. Part No.:
BK1826B
Brand:
BK Precision
Find similar products by selecting one or more attributes.
Select all

Brand

BK Precision

Maximum Frequency

6GHz

Product Type

Frequency Counter

Minimum Frequency

0.001Hz

Resolution

10 Digits

Pulse Width Resolution

20ns

Display Type

LCD

Maximum Input Voltage

30V

Minimum Input Voltage

15V

Input Impedance

50Ω

Minimum Operating Temperature

5°C

Maximum Operating Temperature

40°C

Measurement Time

100s

Standards/Approvals

Complies EN610101, Complies EN61326

Model Number

1826B

Width

10.2 in

Height

3.5in

Connector Type

Type N

Length

235mm

Calibrated

RSCAL

Plug Type

AC Adapter

COO (Country of Origin):
GB
The BK1820B Series Universal Frequency Counters are Compact instruments designed for versatile frequency measurements. They’re equipped with a high-quality temperature-compensated internal frequency reference to provide exceptional stability and accuracy, with a low aging rate of ±1 ppm across the entire temperature range.

Featured on the front is a 0.5 in LCD for displaying frequency, period, ratio, Pulse width, or event count measurements. Multiple input channels allow for precise measurements across a broad range of frequencies. Input A offers flexible signal conditioning, with configurable coupling (AC or DC), input impedance (1 MΩ or 50 Ω), attenuation (1:1 or 5:1), threshold (fully variable) and Active edge. With the BK1826B, an additional input C offers an N-type connector with 50 Ω input impedance and frequency range of 3 GHz to 6 GHz.

3 GHz (BK1823B) and 6 GHz (BK1826B) models

Dedicated microwave channel with N-type connector (BK1826B only)

10-digit display resolution with 0.5 in LCD

±1 ppm time base stability

Internal rechargeable batteries allow for up 24 hours of operating life

Frequency ratio measurement function

Time interval measurement

Remote control with USB (VCOM) Interface

Selectable measurement time, 100 s, 10 s, 1 s, and 0.3 s

Related links