KEMET R46 Metallised Polypropylene Film Capacitor, 310V ac, ±10%, 1μF, Through Hole

Bulk discount available

Subtotal 50 units (supplied in a bag)*

£27.05

(exc. VAT)

£32.45

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 380 unit(s) ready to ship
  • Plus 500 unit(s) shipping from 29 January 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
50 - 90£0.541
100 - 240£0.478
250 - 490£0.415
500 +£0.382

*price indicative

Packaging Options:
RS Stock No.:
875-2273P
Mfr. Part No.:
R463N410050N1K
Brand:
KEMET
Find similar products by selecting one or more attributes.
Select all

Brand

KEMET

Capacitance

1µF

Voltage

310V ac

Mounting Type

Through Hole

Tolerance

±10%

Series

R46

Lead Pitch

22.5mm

Suppression Class

X2

Length

26.5mm

Lead Length

25mm

Depth

11mm

Height

20mm

Dimensions

26.5 x 11 x 20mm

Dielectric

Metallised Polypropylene

Package/Case

50

Lead Diameter

0.8mm

Maximum Operating Temperature

+110°C

Minimum Operating Temperature

-40°C

Dissipation Factor

≤0.1%

KEMET R46 Series


KEMET R46 Series are metallised polypropylene Film Capacitors that have self-healing properties.

Features


Rated voltage: 50/60 Hz
Capacitance range: 0.01 – 10 μF
Lead spacing: 10.0 mm to 37.5 mm
Capacitance tolerance: ±20%, ±10%
Climatic category: 40/110/56, IEC 60068–1
Tape and reel in accordance with IEC 60286–2
Operating temperature range of -40˚C to +110˚C
100% screening factory test at 2200 VDC/1,500 V ac
Self-healing properties

Applications


For worldwide use in electromagnetic interference (EMI) suppression in across-the-line applications requiring X2 safety classification.

Intended for use in situations where capacitor failure would not result in exposure to electric shock. Not for use in "series with mains" type applications.

Standards

EN132400 class X2, UL1414

Warning

Capacitors are designed for connecting directly across a mains supply but should NOT be used in positions where failure of a capacitor would expose anybody to electric shock.

Approvals

ENEC, UL, cUL, CQC