KEMET Environmental Sensor for Industrial, Forest Protection, Infrastructure Protection, Oil, Gas
- RS Stock No.:
- 205-5786
- Mfr. Part No.:
- USEQFCSA391100
- Brand:
- KEMET
Bulk discount available
Subtotal (1 unit)*
£50.08
(exc. VAT)
£60.10
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 - 9 | £50.08 |
| 10 - 24 | £45.52 |
| 25 + | £43.17 |
*price indicative
- RS Stock No.:
- 205-5786
- Mfr. Part No.:
- USEQFCSA391100
- Brand:
- KEMET
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | KEMET | |
| Product Type | Environmental Sensor | |
| Response Time | 12ms | |
| Application | Industrial, Forest Protection, Infrastructure Protection, Oil, Gas | |
| Minimum Supply Voltage | 2.7V | |
| Power Source | Mains | |
| Maximum Supply Voltage | 8V | |
| Pin Count | 3 | |
| Minimum Operating Temperature | -40°C | |
| Package Type | TO-39 | |
| Maximum Operating Temperature | 85°C | |
| Series | QFC | |
| Height | 17.3mm | |
| Standards/Approvals | No | |
| Length | 9.14mm | |
| Width | 9.14 mm | |
| Weight | 650mg | |
| Automotive Standard | No | |
| Select all | ||
|---|---|---|
Brand KEMET | ||
Product Type Environmental Sensor | ||
Response Time 12ms | ||
Application Industrial, Forest Protection, Infrastructure Protection, Oil, Gas | ||
Minimum Supply Voltage 2.7V | ||
Power Source Mains | ||
Maximum Supply Voltage 8V | ||
Pin Count 3 | ||
Minimum Operating Temperature -40°C | ||
Package Type TO-39 | ||
Maximum Operating Temperature 85°C | ||
Series QFC | ||
Height 17.3mm | ||
Standards/Approvals No | ||
Length 9.14mm | ||
Width 9.14 mm | ||
Weight 650mg | ||
Automotive Standard No | ||
- COO (Country of Origin):
- GB
The Kemet QFC pyroelectric flame sensors provide accurate discrimination of flame sources in triple IR flame detection systems, through its excellent signal to noise characteristic at the signature 8 – 10 Hz flicker range of a flame. The sensor element is built into a low noise circuit that has an internal CMOS op amp with a 10 GO feedback resistor outputting a voltage signal centred around half the supply rail. Exceptional high responsivity, a wide field of view and rapid recovery from thermal and electrical shocks makes it the ideal solution for demanding flame detecting applications.
Exceptionally high responsivity
Wide field of view, typically 100° (subject to filter band pass specification)
Rapid recovery from thermal and electrical shock (< 1 second downtime)
TO39 package
Analog output
Integrated op amp
Related links
- KEMET Environmental Sensor for Oil Industrial Infrastructure Protection
- KEMET USEQFCSA391100 Environmental Sensor for Industrial Infrastructure Protection Gas
- KEMET USEQFCSA338100 Environmental Sensor for Oil Industrial Infrastructure Protection
- KEMET Environmental Sensor for Forest Protection Infrastructure Protection Gas
- KEMET Environmental Sensor for Forest Protection Oil Gas
- KEMET USEQFCSA550100 Environmental Sensor for Forest Protection Infrastructure Protection Gas
- KEMET USEQFCSA435100 Environmental Sensor for Forest Protection Oil Gas
- KEMET Environmental Sensor for Forest Protection Oil Gas