XP Power IMA01 DC-DC Converter, 12V dc/ 83.3mA Output, 10.8 → 13.2 V dc Input, 1W, Through Hole, +75°C Max Temp
- RS Stock No.:
- 124-5011
- Mfr. Part No.:
- IMA0112S12
- Brand:
- XP Power
Subtotal (1 unit)*
£6.90
(exc. VAT)
£8.28
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 08 January 2026
Units | Per unit |
---|---|
1 - 4 | £6.90 |
5 - 9 | £6.68 |
10 - 24 | £6.49 |
25 - 49 | £6.28 |
50 + | £6.07 |
*price indicative
- RS Stock No.:
- 124-5011
- Mfr. Part No.:
- IMA0112S12
- Brand:
- XP Power
Select all | Attribute | Value |
---|---|---|
Brand | XP Power | |
Output Voltage | 12V dc | |
Input Voltage Range | 10.8 → 13.2 V dc | |
Power Rating | 1W | |
Input Voltage Nominal | 9 V dc | |
Output Current | 83.3mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 1 | |
Output Voltage Adjustment Range | ±5% | |
Package | SIP 7 | |
Isolation Voltage | 4kV ac | |
Depth | 11.1mm | |
Width | 9.2mm | |
Length | 19.5mm | |
Series | IMA01 | |
Load Regulation | 0.1 | |
Maximum Temperature | +75°C | |
Medical Approved | Yes | |
Minimum Temperature | -40°C | |
Standards Met | CB IEC60601-1, Conducted EN55011 Class B, Conducted Immunity EN61000-4-6, CSA C22.2 No 60601-1, EFT/Burst EN61000-4-4, ESD Immunity EN61000-4-2, Magnetic Fields EN61000-4-8, Radiated EN55011 Class B, Radiated Immunity EN61000-4-3, Surge EN61000-4-5, TUV EN60601-1, UL ANSi/AMMI 60601-1 | |
Select all | ||
---|---|---|
Brand XP Power | ||
Output Voltage 12V dc | ||
Input Voltage Range 10.8 → 13.2 V dc | ||
Power Rating 1W | ||
Input Voltage Nominal 9 V dc | ||
Output Current 83.3mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Output Voltage Adjustment Range ±5% | ||
Package SIP 7 | ||
Isolation Voltage 4kV ac | ||
Depth 11.1mm | ||
Width 9.2mm | ||
Length 19.5mm | ||
Series IMA01 | ||
Load Regulation 0.1 | ||
Maximum Temperature +75°C | ||
Medical Approved Yes | ||
Minimum Temperature -40°C | ||
Standards Met CB IEC60601-1, Conducted EN55011 Class B, Conducted Immunity EN61000-4-6, CSA C22.2 No 60601-1, EFT/Burst EN61000-4-4, ESD Immunity EN61000-4-2, Magnetic Fields EN61000-4-8, Radiated EN55011 Class B, Radiated Immunity EN61000-4-3, Surge EN61000-4-5, TUV EN60601-1, UL ANSi/AMMI 60601-1 | ||
Related links
- XP Power IMA01 DC-DC Converter 21.6 → 26.4 V dc Input Through Hole, +75°C Max Temp
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max Temp
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max Temp
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max Temp
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max Temp
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max Temp
- XP Power IMA01 DC-DC Converter 10.8 → 13.2 V dc Input Through Hole, +75°C Max