Phoenix Contact MCR-S-1-5-UI-DCI-NC Series Current Sensor, 0 11A nominal current, 0 20mA output

Technical Reference
Legislation and Compliance
Non Compliant
COO (Country of Origin): DE
Product Details

Phoenix Contact Current Transducer, MCR-S

The Phoenix Contact MCR-S series of Current Transducer brings you reliable signal conversion, allowing you to push the boundaries of your automation, measurement or control systems. Compact in nature and being able to operate in different temperatures, the MCR-S series offers you the stability needed in your working environment. The device is fully programmable and configurable, perfect for measuring direct, alternating or distorted currents.

Features and Benefits

• Built-in 3 number of inputs, with a current range of 0 A to 11 A (AC/DC)

• Power supply voltage range between 20 V DC to 30 V DC, with a Max. current consumption of less than 40 mA (without load)

• The device can be set up via DIP switches or MCR/PI-CONF-WIN configuration software

• True r.m.s value measurement

• Screw connection, M3 screw thread, 8 mm stripping length

• Different coloured status LED colours, available in green, yellow etc.

• IP20 degree of protection, noise immunity to EN 61000-6-2

• Overvoltage electrical category 3

• CE-compliant

Typical Applications

• Control systems

Specifications
Attribute Value
Output Current Range 0 20mA
Nominal Current 0 11A
Supply Voltage 20 30 V dc
Mounting Type Chassis Mount
Frequency Bandwidth 15 400 Hz
Accuracy <0.5 %
Minimum Operating Temperature -20°C
Series MCR-S-1-5-UI-DCI-NC
Maximum Operating Temperature +60°C
Depth 114.5mm
Height 99mm
Width 22.5mm
21 In stock - FREE next working day delivery available
Price Each
£ 195.05
(exc. VAT)
£ 234.06
(inc. VAT)
Units
Per unit
1 - 4
£195.05
5 - 9
£189.12
10 +
£181.05
Related Products
Measures d.c. and a.c. pulsed and complex currents ...
Description:
Measures d.c. and a.c. pulsed and complex currents with galvanic isolation.,The transducer is capable of measuring nominal currents of 5, 6, 8, 12 and 25A by the use of a set of primary connection pins with an output of 24mA each. The output can be fed through a measuring resistor ...
TLI4970 high-precision current sensors from Infineon are based ...
Description:
TLI4970 high-precision current sensors from Infineon are based on their Hall technology. They are straight-forward, fully digital solutions which do not require external calibration or extra parts to function. Their compact footprint is also made possible by a coreless technology. Suitable applications include; current monitoring, chargers, photovoltaic/general purpose inverters, power ...
Open Loop Hall Effect current transducers with integral ...
Description:
Open Loop Hall Effect current transducers with integral primary connections for the accurate measurement of current. Open Loop (low power consumption)AC,DC, and mixed signal measurement Extended measuring range (3xlpn)Small size HX 03-20 (23.5x15.8x19mm)HX 25-50 (20x19x15.4mm)Multi turn Primary Unipolar power supply Operating Temperature Range -25 to +85°CSupply voltage 12/14Vdc Load Resistance ...
Flexible alternative to the current shunt or transformers ...
Description:
Flexible alternative to the current shunt or transformers for the isolated measurement of a.c. or d.c. currents. Based on the principle of Hall effect and null balance method. Small footprint Measures dc, ac and impulse currents Large primary conductor hole High accuracy Typical applications include; variable speed drives, overcurrent protection, ...