Eaton xStart Contactor, 24 V dc Coil, 3-Pole, 32 A, 15 kW, 3NO, 400 V ac
- RS Stock No.:
- 866-1530
- Mfr. Part No.:
- 277306 DILM32-01(RDC24)
- Brand:
- Eaton
Subtotal (1 unit)*
£184.72
(exc. VAT)
£221.66
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 10 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £184.72 |
*price indicative
- RS Stock No.:
- 866-1530
- Mfr. Part No.:
- 277306 DILM32-01(RDC24)
- Brand:
- Eaton
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Eaton | |
Coil Voltage | 24 V dc | |
Number of Poles | 3 | |
Contact Voltage Rating | 400 V ac | |
Contact Current Rating | 32 A | |
Range | xStart | |
Power Rating | 15 kW | |
Normal State Configuration | 3NO | |
Number Of Auxiliary Contacts | 1 | |
Terminal Type | Screw | |
Width | 45mm | |
Length | 68mm | |
Depth | 97.4mm | |
Mounting Style | DIN Rail Mount | |
Pole and Throw Configuration | 3P | |
Load Current | 32A | |
Input Current | 32A | |
Minimum Operating Temperature | -25°C | |
Control Voltage | 24 → 27 V | |
Maximum Operating Temperature | +50°C | |
Select all | ||
---|---|---|
Brand Eaton | ||
Coil Voltage 24 V dc | ||
Number of Poles 3 | ||
Contact Voltage Rating 400 V ac | ||
Contact Current Rating 32 A | ||
Range xStart | ||
Power Rating 15 kW | ||
Normal State Configuration 3NO | ||
Number Of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Width 45mm | ||
Length 68mm | ||
Depth 97.4mm | ||
Mounting Style DIN Rail Mount | ||
Pole and Throw Configuration 3P | ||
Load Current 32A | ||
Input Current 32A | ||
Minimum Operating Temperature -25°C | ||
Control Voltage 24 → 27 V | ||
Maximum Operating Temperature +50°C | ||
Eaton Contactor, 400V AC Contact Voltage Rating, 68 (L) x 45 (W) x 97.4mm (D) - DILM Series - 277306 XTCE032C01TD
For swift switching with no snags, pick this 3-pole contactor from Eaton. It opens and closes circuits in high-current load systems so they can keep up with your industrial demands. Rapid shift capability and integrated suppressors help prevent damage. This means less time is spent on maintenance and productivity is boosted. You can control this unit directly from a PLC, which saves you from running up and down to make simple settings. As it's not a glutton for power, this instrument is an energy-efficient solution with a 15kW rating.
• Small size of 68 (L) x 45 (W) x 97.4mm (D) for easy installation in tight spaces
• Uniform accessories for convenient expansions or added protection
• Double box for reliable wiring of different cross-sections
• Wide operating temperature range between -25°C and +50°C for use in harsh conditions
• Uniform accessories for convenient expansions or added protection
• Double box for reliable wiring of different cross-sections
• Wide operating temperature range between -25°C and +50°C for use in harsh conditions
What do A1 and A2 mean on a contactor?
These two indicators refer to the different ends of an electromagnetic coil assembly so you can connect the correct terminals to the designated power supplies.
How many auxiliary contacts does this contactor have?
It has one auxiliary contact, so it's simple to install.
Note
Eaton formerly known as Moeller
Eaton XT Series