Siemens SIRIUS Innovation 3RH2 Contactor, 10 A, 4NO, 600 V dc, 690 V ac
- RS Stock No.:
- 136-3670
- Brand:
- Siemens
Subtotal (1 unit)*
£34.08
(exc. VAT)
£40.90
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 27 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £34.08 |
*price indicative
- RS Stock No.:
- 136-3670
- Brand:
- Siemens
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Siemens | |
Contact Voltage Rating | 600 V dc, 690 V ac | |
Contact Current Rating | 10 A | |
Range | SIRIUS Innovation | |
Series | 3RH2 | |
Normal State Configuration | 4NO | |
Number Of Auxiliary Contacts | 4 | |
Terminal Type | Spring Load | |
Length | 45mm | |
Width | 73mm | |
Depth | 69.5mm | |
Minimum Operating Temperature | -25°C | |
Maximum Operating Temperature | +60°C | |
Control Voltage | 220 Vdc | |
Mounting Style | DIN Rail Mount | |
Select all | ||
---|---|---|
Brand Siemens | ||
Contact Voltage Rating 600 V dc, 690 V ac | ||
Contact Current Rating 10 A | ||
Range SIRIUS Innovation | ||
Series 3RH2 | ||
Normal State Configuration 4NO | ||
Number Of Auxiliary Contacts 4 | ||
Terminal Type Spring Load | ||
Length 45mm | ||
Width 73mm | ||
Depth 69.5mm | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature +60°C | ||
Control Voltage 220 Vdc | ||
Mounting Style DIN Rail Mount | ||
- COO (Country of Origin):
- DE
Contactor Relays - 3RH2 Range
Climate-proof, finger safe contactor relays. RC elements, varistors, diodes or diode assemblies (combination of a diode and a Zener diode) can be plugged onto all contactor relays for damping opening surges in the coil.
Size S00
High degree if contact stability at low voltages & current
Suitable for use with solid-state circuits with currents ≥ 1 mA at a voltage of ≥ 17 V
Capable of expansion by up to four contacts through use of snap-on auxiliary switch blocks
High degree if contact stability at low voltages & current
Suitable for use with solid-state circuits with currents ≥ 1 mA at a voltage of ≥ 17 V
Capable of expansion by up to four contacts through use of snap-on auxiliary switch blocks
Note
The OFF-delay of the NO contact and the ON-delay of the NC contact are increased if the contactor coils are attenuated against voltage peaks (noise suppression diode 6 to 10 times; diode assemblies 2 to 6 times, varistor +2 to 5 ms).
Standards
IEC 60947-1, EN 60947-1, IEC 60947-4-1, EN 60947-4-1, IEC 60947-5-1, EN 60947-5-1.