Fluke 902 FC Clamp Meter, 200 μA 600 A 600 V dc 600 V ac CAT III, CAT IV Non-Contact Voltage Detector, RSCAL
- RS Stock No.:
- 917-6698
- Mfr. Part No.:
- FLUKE-902 FC
- Brand:
- Fluke
Subtotal (1 unit)*
£459.00
(exc. VAT)
£550.80
(inc. VAT)
FREE delivery for orders over £60.00
- 6 unit(s) ready to ship
Units | Per unit |
|---|---|
| 1 + | £459.00 |
*price indicative
- RS Stock No.:
- 917-6698
- Mfr. Part No.:
- FLUKE-902 FC
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 200μA | |
| Resistance Resolution | 1Ω | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 6mΩ | |
| Model Number | 902 FC | |
| Resistance Measurement Accuracy | 1 % rgd ± 5 % Digits | |
| AC Current Resolution | 0.1A | |
| DC Voltage Resolution | 100 mV dc | |
| AC Voltage Resolution | 100mV ac | |
| Minimum Operating Temperature | -10°C | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| Temperature Resolution | 0.1°C | |
| AC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| DC Current Accuracy | ±1 % rdg + 4 Digits | |
| DC Current Resolution | 0.1μA | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Temperature Measurement Accuracy | 1 % rgd ± 8 Digits % | |
| Clamp Meter Type | HVAC Clamp Meter | |
| Maximum Operating Temperature | 50°C | |
| Height | 230mm | |
| Length | 45.4mm | |
| Weight | 419g | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIEC 61010-2-033: CAT III 1000 V / CAT IV 600 VIEC 60529: IP30non-operatingFCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11: Group 1Class AKCC: Class A EquipmentFCC: 47 CFR 15 subpart B | |
| Width | 83.7mm | |
| Functions Measured | AC Current, DC Current, Capacitance, AC Voltage, Temperature, Resistance, Continuity, DC Voltage | |
| True RMS | Yes | |
| Non-Contact Voltage Detector | Yes | |
| Maximum Temperature Measurement | 400°C | |
| Maximum AC Current Measurement | 600A | |
| Calibrated | RSCAL | |
| Battery Type | AA Alkaline | |
| Safety Category Level | CAT III, CAT IV | |
| Power Source | Battery | |
| Safety Category Voltage | 600, 300V | |
| Battery Life | 12h | |
| Display Type | LCD | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 200μA | ||
Resistance Resolution 1Ω | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 6mΩ | ||
Model Number 902 FC | ||
Resistance Measurement Accuracy 1 % rgd ± 5 % Digits | ||
AC Current Resolution 0.1A | ||
DC Voltage Resolution 100 mV dc | ||
AC Voltage Resolution 100mV ac | ||
Minimum Operating Temperature -10°C | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
Temperature Resolution 0.1°C | ||
AC Voltage Accuracy ±1 % rdg + 5 Digits | ||
DC Current Accuracy ±1 % rdg + 4 Digits | ||
DC Current Resolution 0.1μA | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Temperature Measurement Accuracy 1 % rgd ± 8 Digits % | ||
Clamp Meter Type HVAC Clamp Meter | ||
Maximum Operating Temperature 50°C | ||
Height 230mm | ||
Length 45.4mm | ||
Weight 419g | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIEC 61010-2-033: CAT III 1000 V / CAT IV 600 VIEC 60529: IP30non-operatingFCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11: Group 1Class AKCC: Class A EquipmentFCC: 47 CFR 15 subpart B | ||
Width 83.7mm | ||
Functions Measured AC Current, DC Current, Capacitance, AC Voltage, Temperature, Resistance, Continuity, DC Voltage | ||
True RMS Yes | ||
Non-Contact Voltage Detector Yes | ||
Maximum Temperature Measurement 400°C | ||
Maximum AC Current Measurement 600A | ||
Calibrated RSCAL | ||
Battery Type AA Alkaline | ||
Safety Category Level CAT III, CAT IV | ||
Power Source Battery | ||
Safety Category Voltage 600, 300V | ||
Battery Life 12h | ||
Display Type LCD | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke Clamp Meter, 600A Maximum AC Current Measurement, 600V Maximum AC Voltage Measurement - FLUKE-902 FC
Features & Benefits
• 600V AC/DC capability allows safe measurement of typical service voltages
• True‑RMS measurement ensures accurate readings on non‑sinusoidal waveforms
• Temperature span to 400°C supports heating element and flue checks
• μA DC range measures low‑level flame sensor currents precisely
• NCV built into the tool permits live‑voltage detection without contact
**Applications**
• Ideal for verifying compressor and fan motor currents on site
• Used for checking flame sensor microcurrents in gas burners
• Can be used to capture temperature and capacitance during maintenance
• Used with preventative maintenance programmes to log historic measurements
How are measurement records captured and shared during inspections?
What battery arrangement and runtime should a field Engineer expect?
How does the meter cope with fluctuating signals during motor start‑up?
What protection ratings and environmental limits apply to the instrument?
Related links
- Fluke 902 FC Clamp Meter, 200 μA 600 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- Fluke 902 FC Clamp Meter, 200 μA 600 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector UKAS
- Fluke A3000 FC Clamp Meter, 400 mA 400 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector RSCAL
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 369 FC Clamp Meter 60 A CAT III Non-Contact Voltage Detector RSCAL
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke A3002 FC Clamp Meter CAT III Non-Contact Voltage Detector RSCAL